Related Experiment Video
Updated: Jan 25, 2026

Manual Construction of a Tissue Microarray using the Tape Method and a Handheld Microarrayer
Published on: June 10, 2022
Application of the LMS method of constructing fetal reference charts: comparison with the original method
Miao-Xu Lun1, Cheng Gui2, Liang Zhang3
1Medical Genetic Centre, Guangdong Women and Children Hospital, Guangzhou, PR China.
Abstract:
Objectives: In view of the concern expressed about the current references, new references for fetal biparietal diameter and head circumference should be constructed for contemporary local populations.Methods: We conducted a retrospective cross-sectional study in two hospitals in Guangdong, Southern China. Fetal biparietal diameter and head circumference percentiles regression were fitted using Cole's LMS method. The BPD and HC data were then transformed into Z-scores that were calculated using two series of reference equations obtained from two methods: Cole's LMS method and the original "mean and SD method." Each Z-score distribution was presented as the mean and standard deviation. Finally, the sensitivity and specificity of each reference for identifying fetuses <2.5th or >97.5th percentile (based on the observed distribution of Z-scores) were calculated. The misclassified number and Youden's index were listed.Results: A total of 17,974 biparietal diameter and 18,269 head circumference measurements were chosen to establish a reference chart. The LMS method could fit the local population better than the "mean and SD method" as it had a lower number of misclassified fetuses and a higher Youden's index.Conclusion: The Cole's LMS method was able to construct a satisfied reference range of fetal head sizes in Southern China.
Related Concept Videos
Methods of Documentation IV: Focus Charting
It typically involves three columns for recording information:
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Run Charts
The R Chart
R charts are pivotal for pinpointing shifts in process variability. Stability is indicated when all data points remain within the defined upper and lower...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Interpreting R Charts
An R chart plots the range of subsets of measurements collected from a process. Each point on the chart represents the range—defined as the difference between the maximum and minimum...

