Abstract:
A major limitation of the single antigen bead (SAB) assay is the so called prozone effect, whereby the detection of high titer complement fixing HLA antibodies is compromised due to complement split product (from C3 and C4 components) deposition and interference with the reporter anti-IgG-PE antibody binding. Strategies to minimize prozone include serum titration or treatment with heat, dithiotreitol (DTT), or ethylenediaminetetraacetic acid (EDTA). While effective, these treatments may compromise HLA antibody binding and detection. Here we describe the Dual Antibody Rapid Test (DART), a modified version of the rapid optimized SAB (ROB) protocol, in which we use an IgG-PE/C3d-PE antibody cocktail to simultaneously detect bead bound IgG and C3d, which allows for detection of HLA antibodies independent of the prozone effect. Twenty prozone positive sera (10 class I and 10 class II), identified by titration, were tested by the ROB protocol, with or without EDTA pre-treatment, using three reporter antibody cocktails: (1) IgG-PE, (2) C3d-PE, or (3) IgG-PE/C3d-PE (DART). Mean fluorescence intensity (MFI) values were then compared. IgG negative (n = 735) vs IgG positive (n = 1185) reactions were identified using a 1000 MFI IgG EDTA cutoff. IgG positive reactions were classified based on ΔMFI (IgG EDTA - IgG) as follows: (1) prozone negative (ΔMFI < 3000; n = 737), (2) slight prozone (ΔMFI 3001-5000; n = 49), (3) moderate prozone (ΔMFI 5001-10,000; n = 93), and (4) marked prozone (ΔMFI > 10,001; n = 306). No C3d deposition was present on IgG negative beads, and the majority of prozone positive specificities (438/448; 98%) fixed complement and were detected with the C3d-PE reporter. Interestingly, C3d-PE MFI was directly proportional to the degree of prozone (mean C3d-PE MFI = 4419.5 ± 1606.3 for slight, 5991.0 ± 2302.7 for moderate, and 12,417.4 ± 2969.9 for marked prozone specificities). Interestingly, EDTA treatment was found to have a negative impact on MFI of up to 15% of prozone negative specificities. Importantly, the DART protocol detected all prozone positive specificities while MFI for prozone negative specificities correlated well with those seen with the IgG-PE reporter alone (R2 = 0.97). In conclusion, the DART protocol accurately detects HLA antibodies independent of the prozone effect. Implementation of DART is an easy way to overcome the prozone effect without compromising HLA antibody detection.
Related Concept Videos
Development of Antibiotic Resistance
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Resistivity
Resistance
Resistance and Conductance
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...
Equivalent Resistance