Related Experiment Video
Updated: Jan 25, 2026

Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
Published on: July 23, 2016
Computed tomography measurements of intraocular structures of the feline eye
Shawn Sreenivasan Chandrakumar1, Alex Zur Linden2, Mark Owen1,3
1School of Veterinary Science, Massey University, Palmerston North, New Zealand.
Abstract:
Diagnostic imaging of the eye can be performed using ultrasonography, MRI or CT. This study describes the CT dimensions, volumes and radiodensities of presumed normal feline intraocular structures. Nineteen adult patients were included in this retrospective study. Fourteen males and five females were included, with domestic short hair (DSH) being the predominant breed. Length, volume and radiodensity values for the lens, anterior chamber, vitreous chamber and optic nerve were calculated as well as measurements of the optic nerve width. There was no significant correlation found on linear regression analysis comparing patient's body weight with the various ocular measurements. Measurements of the lens, globe and optic nerve had significant differences (P<0.05) noted between the sexes, with males having increased values. These results may be skewed due to the large majority of male patients in the study. There was a weak correlation found between age and right eye (OD) optic nerve width, with an increase in the optic nerve width noted with increasing age. The findings of this study are a first step in establishing CT reference values for feline intraocular structure measurements.
More Related Videos
11:49Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
10:10Ultrahigh Resolution Mouse Optical Coherence Tomography to Aid Intraocular Injection in Retinal Gene Therapy Research
Published on: November 2, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Accessory Structures of the Eye
Imaging Studies III: Computed Tomography
Muscles of the Eye
Extraocular Muscles
The six extraocular muscles surround the eyeball and control its movements. They are responsible for a wide range of eye motions, including looking up, down, left, right, and...
Design Example: Traverse Angle Computations
Structures of Solids