Related Experiment Video
Updated: Aug 25, 2026

Accurate and Simple Evaluation of Vascular Anastomoses in Monochorionic Placenta using Colored Dye
Published on: September 5, 2011
Acid-base evaluation of umbilical cord blood: relation to delivery mode and Apgar scores
Acid-base status of umbilical artery and vein blood was measured immediately after delivery in 300 cases. A slight acidosis of mixed respiratory/metabolic type was found in newborns delivered following a second stage of 10-30 min duration. After a second stage of more than 30 min the metabolic contribution to the acidosis was predominating. With Apgar scores lower than 10 the pH was found to decrease and carbon dioxide tension to increase. Induction or augmentation of labor by oxytocin did not influence the acid-base status of umbilical cord blood. Delivery by vacuum extraction or low forceps resulted in lower pH and higher carbon dioxide tension in umbilical cord blood, but the changes were associated with the indication for instrumental delivery and not with mode of delivery. A large arterio-venous difference between the acid-base parameters was usually connected to vigorous newborns and a small difference to depressed infants. The carbon dioxide tension was usually increased in newborns with decreased pH, and a close correlation between these parameter was found. No case of acidosis (pH below 7.15) was found in this population at carbon dioxide tensions below 7.2 kPa; at higher Pco2 values only 25% of the newborns were acidotic. A Pco2 level of 7.7 kPa might be used at transcutaneous carbon dioxide monitoring during labor, although the sensitivity and specificity of this parameter will have to be decided in a prospective study.
Acid-base status of umbilical artery and vein blood was measured immediately after delivery in 300 cases. A slight acidosis of mixed respiratory/metabolic type was found in newborns delivered following a second stage of 10-30 min duration. After a second stage of more than 30 min the metabolic contribution to the acidosis was predominating. With Apgar scores lower than 10 the pH was found to decrease and carbon dioxide tension to increase. Induction or augmentation of labor by oxytocin did not influence the acid-base status of umbilical cord blood. Delivery by vacuum extraction or low forceps resulted in lower pH and higher carbon dioxide tension in umbilical cord blood, but the changes were associated with the indication for instrumental delivery and not with mode of delivery. A large arterio-venous difference between the acid-base parameters was usually connected to vigorous newborns and a small difference to depressed infants. The carbon dioxide tension was usually increased in newborns with decreased pH, and a close correlation between these parameter was found. No case of acidosis (pH below 7.15) was found in this population at carbon dioxide tensions below 7.2 kPa; at higher Pco2 values only 25% of the newborns were acidotic. A Pco2 level of 7.7 kPa might be used at transcutaneous carbon dioxide monitoring during labor, although the sensitivity and specificity of this parameter will have to be decided in a prospective study.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...

