Related Experiment Video
Updated: Jan 25, 2026

A Novel Tenorrhaphy Suture Technique with Tissue Engineered Collagen Graft to Repair Large Tendon Defects
Published on: December 10, 2021
Sternoclavicular Joint Reconstruction Fracture Risk Is Reduced With Straight Drill Tunnels and Optimized With Tendon
Frank Martetschläger1,2, Franziska Reifenschneider3, Nicole Fischer3
1Department of Orthopaedic Sports Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
Background:
Despite the rare entity of sternoclavicular joint (SCJ) instability, a variety of different reconstruction techniques for SCJ dislocations have been described. A technique with oblique drilling has been proposed to reduce intraoperative risks.
Purpose:
To biomechanically investigate different cerclage reconstruction techniques and the benefit of additional reinforcement using suture tape.
Study Design:
Controlled laboratory study.
Methods:
Reconstructed artificial bone specimens were mounted on a mechanical testing machine. They were subjected to anterior and posterior translation, analyzing ultimate strength, displacement, stiffness, and elongation. For stage 1, different angulations of the drill tunnels through the sternum and clavicle were compared. Straight drill tunnels from anterior to posterior were compared with 45° oblique drill tunnels. For stage 2, three different materials for cerclage reconstruction were compared: (1) suture tape alone (FT group), (2) tendon graft alone (tendon group), and (3) tendon graft with suture tape augmentation (tendon+FT group).
Results:
For the FT group, in the anterior and posterior directions, straight drill holes resulted in a significantly higher load to failure (936.9 ± 122.5 N) compared with oblique ones (434.5 ± 20.2 N) (P < .0001). During cyclic testing, all specimens with straight drill holes survived the 5- to 550-N step, while all specimens with oblique ones failed during the 5- to 450-N step. Analyzing the graft material choice, the mean load to failure was 556.6 ± 174.3 N for the tendon group, 936.9 ± 122.5 N for the FT group, and 767.0 ± 110.7 N for the tendon+FT group (P = .089). The stiffness of the tendon+FT group was significantly lower than that of the FT group and significantly higher than that of the tendon group.
Conclusion:
Oblique tunnel placement during SCJ reconstruction, while reducing the intraoperative risk, results in decreased primary stability of the construct. Tendon graft reconstruction with suture tape augmentation leads to enhanced stability and optimizes biomechanical properties of the construct.
Clinical Relevance:
The surgical technique with straight drill holes has superior initial biomechanical properties and may likewise produce superior clinical outcomes in the treatment of SCJ instability. Suture tape augmentation can provide additional stability to reconstruction procedures.
Related Concept Videos
Generation of Straight or Branched Actin Filaments
Arp2/3 Complex
Arp2/3 complex is a seven-subunit complex consisting of two proteins similar to actin- Arp2 and Arp3, and five other subunits that help keep Arp2 and Arp3 inactive. When required, the complex is...
Structural Joints: Synovial Joints
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Structural Joints: Cartilaginous Joints
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary...
Joints
Structural joint classifications are based on the material that makes up the joint as well as whether or not the joint contains a space between the bones. Joints are structurally classified as fibrous, cartilaginous, or synovial.
Fibrous Joints Are Immovable
The bones of a...
Magnetic Field Due To A Thin Straight Wire

