Related Experiment Video
Updated: Jan 25, 2026

A Mobile Outside-in Technique of Transforaminal Lumbar Endoscopy for Lumbar Disc Herniations
Published on: August 7, 2018
Development of a Biconcave Mobile-Bearing Lumbar Total Disc Arthroplasty Concept Using Finite Element Analysis and
Chaochao Zhou1, Ryan Willing1,2
1Department of Mechanical Engineering, State University of New York at Binghamton, Binghamton, New York.
Abstract:
Total disc arthroplasty (TDA) is a motion-preserving surgical treatment for spinal disorders. However, adverse surgical outcomes, such as abnormal kinematics, facet joint (FJ) overloading, and polyethylene (PE) failures, have limited wide application of lumbar TDAs. The objectives of this computational study were to elucidate how implant design and FJ articulation both influence metal-on-polyethylene (MoP) motion and contact mechanics, as well as to propose and refine a new mobile-bearing TDA concept which enhanced postoperative performance. Simulation results show that abnormal motions (lift-off and/or unsymmetrical motion) are alleviated in fixed-/mobile-bearing TDA-treated segments, as the FJ gap increases. It clearly demonstrates that FJ articulation guides segmental motion and interferes with intended MoP articulation. For an existing biconvex mobile-bearing design, component impingement leads to a peak PE stress of 20.8 MPa (yield stress: 13 MPa), indicating a high risk of PE creep/fracture. Therefore, we proposed a new TDA concept featuring a biconcave PE core with a smooth shape, in order to strengthen the PE rim and mitigate edge-loading. Furthermore, the biconcave-core TDA was optimally designed to promote normal segmental range of motion (ROM), or to minimize polyethylene contact pressure (PCP). In extension (the severest loading scenario), the biconvex-core TDA design caused a ROM 3.6° (+88%) greater than the intact segment and a peak PCP of 116.5 MPa. In contrast, ROM-optimal or PCP-optimal biconcave-core TDA designs decreased the ROM difference to 0.0° or the peak PCP to 24.3 MPa. Therefore, this new TDA design can potentially reduce the incidence of hypermotion and PE damage. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1805-1816, 2019.
Related Concept Videos
Formula Mass and Mole Concepts of Compounds
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Sustainable Development
Elements and Compounds
Elements
Elements are classified as atomic or molecular based on the nature of their basic units. They are unique forms of matter with specific chemical and physical properties that cannot break down into smaller substances by ordinary chemical reactions. There...
Self-Concept
Infancy and Emerging Recognition
During infancy, self-concept is virtually nonexistent. Babies do not distinguish themselves as separate entities and often mistake their...
Classification of Elements and Compounds
Compounds are pure substances composed of two or more elements in fixed, definite proportions. Compounds are classified as ionic or molecular (covalent) based on the bonds...

