Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Dynamic Control of Gas Chromatographic Selectivity during the Analysis of Organic Bases
Ernest Darko1, Kevin B Thurbide1
1Department of Chemistry , University of Calgary , 2500 University Drive, NW , Calgary , Alberta T2N 1N4 , Canada.
Abstract:
A novel method for controlling selectivity during the gas chromatographic (GC) analysis of organic bases is presented. The technique employs tandem stainless steel capillary columns, each coated with a pH adjusted water stationary phase. The first is a 0.5 m trap column coated with a pH 2.2 phase, while the second is an 11 m analytical column coated with a pH 11.4 phase. The first column traps basic analytes from injected samples, while the remaining components continue to elute and separate. Then, upon injection of a volatile aqueous ammonia solution, the basic analytes are released as desired to the analytical column where they are separated and analyzed. Separations are quite reproducible and demonstrate an average RSD of 1.2% for analyte retention times in consecutive trials. Using this approach, the retention of such analytes can be readily controlled and they can be held in the system for periods of up to 1 h without significant erosion of peak shape. As such, it can provide considerable control over analyte selectivity and resolution compared to conventional separations. Further, by employing a third conventional GC column to the series, both traditional hydrocarbon and enhanced organic base separations can be performed. The method is applied to the analysis of complex mixtures, such as gasoline, and much less matrix interference is observed as a result. The findings indicate that this approach could be a useful alternative for analyzing such samples.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
08:58Procedures of Laboratory Fumigation for Pest Control with Nitric Oxide Gas
Published on: November 24, 2017
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...