Related Experiment Video
Updated: Jan 25, 2026

Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Low-energy/pulse response and high-resolution-CMOS camera for spatiotemporal femtosecond laser pulses
Jennyfer Zapata-Farfan1, Ramiro Contreras-Martínez1, Martha Rosete-Aguilar1
1Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México (UNAM) Circuito Exterior, Cd. Universitaria, 04510 Ciudad de México, Mexico.
Abstract:
In this work, we present a commercial CMOS (Complementary Metal Oxide Semiconductor) Raspberry Pi camera implemented as a Near-Infrared detector for both spatial and temporal characterization of femtosecond pulses delivered from a femtosecond Erbium Doped Fiber laser (fs-EDFL) @ 1.55 µm, based on the Two Photon Absorption (TPA) process. The capacity of the device was assessed by measuring the spatial beam profile of the fs-EDFL and comparing the experimental results with the theoretical Fresnel diffraction pattern. We also demonstrate the potential of the CMOS Raspberry Pi camera as a wavefront sensor through its a nonlinear response in a Shack-Hartmann array and for the temporal characterization of the femtosecond pulses delivered from the fs-EDFL through TPA Intensity autocorrelation measurements. The direct pulse detection and measurement, through the nonlinear response with a CMOS, is proposed as a novel and affordable high-resolution and high-sensitivity alternative to costly detectors such as CCDs, wavefront sensors and beam profilers @ 1.55 µm. The measured fluence threshold, down to 17.5 µJ/cm2, and pJ/pulse energy response represents the lowest reported values applied as a beam profiler and a TPA Shack-Hartmann wavefront sensor, to our knowledge.
More Related Videos
10:27Fabrication of Nano-engineered Transparent Conducting Oxides by Pulsed Laser Deposition
Published on: February 27, 2013
12:00Synthesis of Gold Nanoparticle Integrated Photo-responsive Liposomes and Measurement of Their Microbubble Cavitation upon Pulse Laser Excitation
Published on: February 24, 2016
Related Concept Videos
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Regulation of Pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...