Related Experiment Video
Updated: Jan 25, 2026

Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
Balloon Guide Catheter Is Beneficial in Endovascular Treatment Regardless of Mechanical Recanalization Modality
Jang-Hyun Baek1,2, Byung Moon Kim3, Dong-Hun Kang4,5
1From the Department of Neurology, Kangbuk Samsung Hospital (J.-H.B.), Sungkyunkwan University School of Medicine, Seoul, Korea.
Insights
Balloon guide catheters (BGCs) improve outcomes in endovascular stroke treatment. Using BGCs significantly increases successful recanalization rates and leads to better functional outcomes, regardless of the thrombectomy technique employed.
Area of Science:
- Neurology
- Interventional Radiology
- Cardiovascular Medicine
Background:
- Endovascular treatment is a key therapy for acute ischemic stroke.
- Balloon guide catheters (BGCs) are utilized in endovascular procedures.
- The benefit of BGCs across different mechanical recanalization modalities is not fully established.
Purpose of the Study:
- To evaluate the efficacy of balloon guide catheters (BGCs) in endovascular stroke treatment.
- To determine if BGC use improves outcomes irrespective of the primary mechanical recanalization method (stent retriever thrombectomy or thrombaspiration).
Main Methods:
- Retrospective review of 955 acute stroke patients from 17 stroke centers.
- Patients were categorized into BGC and non-BGC groups.
- Multivariable analyses were performed to adjust for the type of first-line endovascular modality.
Main Results:
- The BGC group showed significantly higher successful recanalization rates (86.8% vs. 74.7%).
- First-pass recanalization was more frequent (37.0% vs. 14.1%) with fewer device passes and shorter procedural times in the BGC group.
- BGC use was an independent predictor of successful recanalization (OR, 2.18) and favorable outcome (OR, 1.40).
Conclusions:
- Balloon guide catheter use enhances successful recanalization in endovascular stroke treatment.
- BGCs improve functional outcomes for stroke patients.
- The benefits of BGCs are consistent across both stent retriever thrombectomy and thrombaspiration modalities.
Abstract:
Background and Purpose- Based on its mechanism, the use of balloon guide catheters (BGCs) may be beneficial during endovascular treatment, regardless of the type of mechanical recanalization modality used-stent retriever thrombectomy or thrombaspiration. We evaluated whether the use of BGCs can be beneficial regardless of the first-line mechanical endovascular modality used. Methods- We retrospectively reviewed consecutive acute stroke patients who underwent stent retriever thrombectomy or thrombaspiration from the prospectively maintained registries of 17 stroke centers nationwide. Patients were assigned to the BGC or non-BGC group based on the use of BGCs during procedures. Endovascular and clinical outcomes were compared between the BGC and non-BGC groups. To adjust the influence of the type of first-line endovascular modality on successful recanalization and favorable outcome, multivariable analyses were also performed. Results- This study included a total of 955 patients. Stent retriever thrombectomy was used as the first-line modality in 526 patients (55.1%) and thrombaspiration in 429 (44.9%). BGC was used in 516 patients (54.0%; 61.2% of stent retriever thrombectomy patients; 45.2% of thrombaspiration patients). The successful recanalization rate was significantly higher in the BGC group compared with the non-BGC group (86.8% versus 74.7%, respectively; P<0.001). Furthermore, the first-pass recanalization rate was more frequent (37.0% versus 14.1%; P<0.001), and the number of device passes was fewer in the BGC group (2.5±1.9 versus 3.3±2.1; P<0.001). The procedural time was also shorter in the BGC group (54.3±27.4 versus 67.6±38.2; P<0.001). The use of BGC was an independent factor for successful recanalization (odds ratio, 2.18; 95% CI, 1.54-3.10; P<0.001) irrespective of the type of first-line endovascular modality used. The use of BGC was also an independent factor for a favorable outcome (odds ratio, 1.40; 95% CI, 1.02-1.92; P=0.038) irrespective of the type of first-line endovascular modality used. Conclusions- Regardless of the first-line mechanical endovascular modality used, the use of BGC in endovascular treatment was beneficial in terms of both recanalization success and functional outcome.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
06:30Complete and Partial Resuscitative Endovascular Balloon Occlusion of the Aorta for Hemorrhagic Shock
Published on: May 19, 2022
Related Concept Videos
Sensory Modalities
General senses refer to the broad category of sensory information detected by receptors in the body and can be further grouped into somatic and visceral senses. Somatic sensations include touch, pressure, temperature, and pain and are essential for navigating our environment and...
Reaction Mechanisms
For instance, the decomposition of ozone appears to follow a mechanism with two steps:
Mechanical Protein Functions
Mechanism of Conjugation
Mechanical Systems
Compensation Mechanisms
Respiratory Compensation
This mechanism addresses metabolic-induced pH imbalances by adjusting breathing rates. Respiratory compensation begins within minutes of detecting a pH...