Contrast-enhanced endoscopic ultrasound for the differential diagnosis between benign and malignant lymph nodes: a
Andrea Lisotti1, Claudio Ricci2, Marta Serrani1
1Gastroenterology Unit, Department of Medical and Surgical Sciences, University of Bologna, Hospital of Imola, Imola, Bologna, Italy.
Abstract:
Background The differential diagnosis between benign and malignant lymph nodes (LNs) is crucial for patient management and clinical outcome. The use of contrast-enhanced endoscopic ultrasound (EUS) has been evaluated in several studies with diverse results. The aim of this meta-analysis was to evaluate the pooled diagnostic accuracy of contrast-enhanced EUS (CE-EUS) and contrast-enhanced harmonic EUS (CH-EUS) in this setting. Methods A systematic electronic search was performed, including all original papers dealing with assessment of the nature of the LNs using CE-EUS or CH-EUS. A meta-analysis was performed to obtain pooled sensitivity, specificity, positive and negative likelihood ratio, and diagnostic odds ratio. The Summary Receiver Operating Characteristic (ROC) Curve method was used to calculate the area under the curve. Statistical analysis was carried out using Meta-Disc V.1.4, Stata V.12.0 and Review Manager V.5.2. Results Among 210 pertinent studies, four (336 patients) were included in the analysis. The pooled sensitivity was 82.1 % (75.1 - 87.7 %) and pooled specificity was 90.7 % (85.9 - 94.3 %) with significant heterogeneity found in sensitivity; the positive-likelihood ratio (LR) was 7.77 (5.09 - 11.85) and the negative-LR was 0.15 (0.05 - 0.46); the pooled diagnostic odds ratio (DOR) was 54 (15 - 190). Subgroup analysis including studies performed using CH-EUS (two studies, 177 LNs) showed a pooled sensitivity of 87.7 % (77.0 - 93.9 %) and a pooled specificity of 91.8 % (84.5 % - 96.4 %) with no significant heterogeneity; the pooled positive-LR was 9.51 (4.95 - 18.28) and the pooled negative-LR was 0.14 (0.06 - 0.35); pooled DOR was 68.42 (15.5 - 301.4). Conclusions From these data, CE-EUS is not recommended due to inadequate sensitivity. On the other hand, CH-EUS studies showed optimal accuracy (pooled sensitivity 87.7 % and specificity 91.8 %), comparable to elastography and even EUS-guided fine needle aspiration (EUS-FNA), suggesting a role in the diagnostic algorithm.
More Related Videos
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Directing Effect of Substituents: meta-Directing Groups
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...