Left ventricle function assessment using gated first-pass 18F-FDG PET: Validation against equilibrium radionuclide
Fayçal Ben Bouallègue1,2, Laurent Maïmoun3,4, Florentin Kucharczak5
1Nuclear Medicine Department, Lapeyronie University Hospital, Avenue du Doyen Giraud 371, 34295, Montpellier Cedex 5, France. faycal.ben-bouallegue@umontpellier.fr.
Gated first-pass 18F-FDG PET offers a reliable method for assessing left ventricle (LV) function, serving as a viable alternative to equilibrium radionuclide angiography (ERNA) in oncologic patients.
Area of Science:
- Nuclear Medicine
- Cardiovascular Imaging
- Oncology
Background:
- Left ventricle (LV) function assessment is crucial for monitoring patients undergoing cardiotoxic chemotherapy.
- Equilibrium radionuclide angiography (ERNA) is a standard method, but gated first-pass 18F-FDG PET offers potential advantages.
Purpose of the Study:
- To evaluate the feasibility of assessing LV function using gated first-pass 18F-FDG PET.
- To compare the concordance of LV function measurements obtained by PET with those from ERNA.
Main Methods:
- Twenty-four oncologic patients underwent both ERNA (planar and SPECT) and gated first-pass 18F-FDG PET.
- PET images were processed in pseudo-planar and fully-tomographic modes for LV function analysis.
- Concordance and reproducibility were assessed using statistical methods like Lin's concordance correlation coefficient (ccc) and Bland-Altman analysis.
Main Results:
- Pseudo-planar PET EF estimates showed good concordance with planar ERNA (ccc = 0.81).
- Fully-tomographic PET measurements were highly concordant with SPECT ERNA for LV EDV (ccc = 0.83), ESV (ccc = 0.92), and EF (ccc = 0.89).
- Reproducibility was excellent and comparable between PET and ERNA for both methods.
Conclusions:
- Gated first-pass 18F-FDG PET is a feasible and accurate method for LV function assessment.
- It presents a relevant alternative to ERNA, allowing simultaneous evaluation of therapeutic response and cardiac toxicity.
- This technique is particularly valuable for oncologic patients receiving cardiotoxic chemotherapy.
Related Concept Videos
First Pass Effect
Depending on the route of administration, drugs can be metabolized in the liver, intestine, lungs, and vasculature. Orally administered drugs are first absorbed through the...
Dynamic Equilibrium
Solution Equilibrium and Saturation
Free Energy and Equilibrium
Recall that Q is the numerical value of the mass action...
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
Calculating Equilibrium Concentrations
A more...

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)