Nonsupine Positioning after Macular Hole Surgery: A Prospective Multicenter Study
Related Experiment Video
Updated: Jan 25, 2026

Regenerative Therapy by Suprachoroidal Cell Autograft in Dry Age-related Macular Degeneration: Preliminary In Vivo Report
Published on: February 12, 2018
Birger Lindtjørn1, Jørgen Krohn2, Dordi Austeng3
1Department of Ophthalmology, Stavanger University Hospital, Stavanger, Norway.
Purpose:
To evaluate the postoperative closure rate of full-thickness macular holes (MHs) after nonsupine positioning, which means that the patients avoid upward gaze and a supine sleeping position, and to investigate the correlation between postoperative positioning compliance and closure rate.
Design:
Prospective, multicenter study (ClinicalTrials.gov identifier, NCT02295943).
Participants:
Patients undergoing primary surgery for primary MH.
Methods:
Patients underwent pars plana vitrectomy with internal limiting membrane peeling and sulfur hexafluoride gas tamponade followed by 3 to 5 days of nonsupine positioning. A positioning measuring device that recorded the time spent in the supine position was attached to patients' forehead after surgery for 24 hours.
Main Outcome Measures:
Anatomic closure rate of MH at 2 weeks or more after surgery and the time spent in supine position during the first 24 hours after surgery.
Results:
A total of 205 participants were included, of whom 2 were lost to follow-up. Two hundred two of 203 MHs closed after a single operation, giving a closure rate of 99.5% (95% confidence interval, 97.3%-99.9%). The median time of supine positioning during the first 24 hours was 28 seconds (range, 0:00:00-01:52:28). Because of the very high closure rate, a correlation between positioning compliance and closure rate could not be established.
Conclusions:
Pars plana vitrectomy with internal limiting membrane peeling followed by a short-term nonsupine positioning accomplished a very high MH closure rate. Thus, face-down positioning was not necessary to achieve excellent closure rates in this study.
More Related Videos
Related Concept Videos
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Position-effect Variegation
Position and Displacement
Serial Position Effect
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Position Vectors
For instance, we want to locate a point P(x, y, z) relative to the origin of coordinates O. In that case, we can define a position...

