Related Experiment Video
Updated: Jan 25, 2026

3D Ultrasound Imaging: Fast and Cost-effective Morphometry of Musculoskeletal Tissue
Published on: November 27, 2017
On-the-fly extrinsic calibration of multimodal sensing system for fast 3D thermographic scanning
Abstract:
The fusion of three-dimensional (3D) geometrical and two-dimensional (2D) thermal information provides a promising method for characterizing temperature distribution of 3D objects, extending infrared imaging from 2D to 3D to support various thermal inspection applications. In this paper, we present an effective on-the-fly calibration approach for accurate alignment of depth and thermal data to facilitate dynamic and fast-speed 3D thermal scanning tasks. For each pair of depth and thermal frames, we estimate their relative pose by minimizing the objective function that measures the temperature consistency between a 2D infrared image and the reference 3D thermographic model. Our proposed frame-to-model mapping scheme can be seamlessly integrated into a generic 3D thermographic reconstruction framework. Through graphics-processing-unit-based acceleration, our method requires less than 10 ms to generate a pair of well-aligned depth and thermal images without hardware synchronization and improves the robustness of the system against significant camera motion.
More Related Videos
08:49Author Spotlight: Unveiling the Potential of VSFG Microscopy in Studying Mesoscopically Heterogeneous Self-Assembled Structures
Published on: December 1, 2023
07:47Author Spotlight: 3D Scanning and Augmented Reality for Enhanced Cancer Surgery Communication
Published on: December 15, 2023
Related Concept Videos
The Extrinsic Apoptotic Pathway
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Leaky Scanning