Related Experiment Video
Updated: Jan 25, 2026

Tactile Vibrating Toolkit and Driving Simulation Platform for Driving-Related Research
Published on: December 18, 2020
Temperature perturbation related to the invisible ink vibrationally excited nitric oxide monitoring (VENOM)
Abstract:
The limits of applicability of the invisible ink variant of the vibrationally excited nitric oxide monitoring (VENOM) technique for three distinct flow fields is reported in this work. This technique involves the generation of a grid of vibrationally excited NO (X,Π2) by exciting the NO A-X electronic transition at 226 nm, which subsequently relaxes via fluorescence and collisional quenching to produce vibrationally excited NO (X,Π2). This grid is then probed by two laser sheets tuned to distinct rotational states. The resulting images allow for the simultaneous measurement of temperature and velocity. The flow fields presented in this work provide a range of NO concentrations, vibrational lifetimes, pressures, temperatures, and collisional quenching, which explore the applicability of the invisible ink variant to a wide range of conditions. We have modelled the initial NO, O2, and N2 vibrational and rotational energy distribution resulting from the combination of fluorescence and quenching of electronically excited NO. The subsequent rethermalization of the sample, in particular the long-time vibrational relaxation, has been modelled using a forced harmonic oscillator model. The time-dependent temperature perturbation due to the invisible ink technique is evaluated for two distinct timescales: a short-timescale temperature rise resulting from collisional quenching and rotational/translational thermalization and a long-timescale temperature rise caused by vibrational thermalization. Under low pressures where fluorescence dominates quenching, there is minimal temperature perturbation of the flow field on the timescale of a VENOM measurement, and the short-timescale temperature perturbation only becomes significant at high NO seed concentrations. The predicted signal-to-noise ratio of the invisible ink method is unaffected for low-pressure, low-temperature flow fields. However, preserving signal-to-noise ratio for a high-temperature, high-pressure flow field could prove challenging due to the impact of quenching and self-absorption. Overall, we find that the invisible ink method is predicted to be a viable laser-based diagnostic for velocimetry and thermometry over a wide range of experimental conditions.
Related Concept Videos
Nitric Oxide Signaling Pathway
Vibrating Concrete
Oxidation Numbers
Pyruvate Oxidation
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Oxidation-Reduction Reactions

