Multi-pass approach to reduce cone-beam artifacts in a circular orbit cone-beam CT system
Abstract:
We propose a multi-pass approach to reduce cone-beam artifacts in a circular orbit cone-beam computed tomography (CT) system. Employing a large 2D detector array reduces the scan time but produces cone-beam artifacts in the Feldkamp, Davis, and Kress (FDK) reconstruction because of insufficient sampling for exact reconstruction. While the two-pass algorithm proposed by Hsieh is effective at reducing cone-beam artifacts, the correction performance is degraded when the bone density is moderate and the cone angle is large. In this work, we treated the cone-beam artifacts generated from bone and soft tissue as if they were from less dense bone objects and corrected them iteratively. The proposed method was validated using a numerical Defrise phantom, XCAT phantom data, and experimental data from a pediatric phantom followed by image quality assessment for FDK, the two-pass algorithm, the proposed method, and the total variation minimization-based iterative reconstruction (TV-IR). The results show that the proposed method was superior to the two-pass algorithm in cone-beam artifact reduction and effectively reduced the overcorrection by the two-pass algorithm near bone regions. It can also be observed that the proposed method produced better correction performance with fewer iterations than the TV-IR algorithm. A qualitative evaluation with mean-squared error, structural similarity, and structural dissimilarity demonstrated the effectiveness of the proposed method.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Related Concept Videos
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Principal Stresses in a Beam
Analyzing principal stresses is crucial, especially in...
Beams with Symmetric Loadings
The M/EI...
Energy of a Satellite in a Circular Orbit
