Speech level parameters in very low and excessive reverberation measured with a contact-sensor-based device and a
Arianna Astolfi1, Antonella Castellana2, Giuseppina Emma Puglisi1
1Politecnico di Torino, Department of Energy, Corso Duca degli Abruzzi, 24, 10129, Torino, Italy.
Abstract:
This work deals with the effect of very low and excessive reverberation on speech sound pressure levels. Measurements were carried out in a semi-anechoic and reverberant room using a contact-sensor-based device fixed at the base of the neck and a headworn microphone placed at 2.5 cm from the speaker's mouth. Speakers produced short monologues and also described a map with the intent of correctly explaining directions to a listener 6 m away. A significant increase of about 2 dB in mean, equivalent, and mode speech levels in semi-anechoic compared to reverberant room was on average observed for the map description from recordings with the contact device, thus, highlighting an increased vocal intensity in dead rooms when the speech task had a communicative intent. Such reliable results were not found with the headworn microphone because speech levels were affected by noise recorded in the pauses. Particularly, the 30 ms logging interval brought to more severe errors in mode and mean speech levels compared to 1 s. When the pauses were removed and a logging interval of 30 ms was adopted, results were more consistent with those obtained with the contact sensor, but level differences between the two rooms still remained not significant.
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Excess Pressure Inside a Drop and a Bubble