Related Experiment Video
Updated: Jan 25, 2026

Fabrication of Thin Film Silver/Silver Chloride Electrodes with Finely Controlled Single Layer Silver Chloride
Published on: July 1, 2020
Sterility of Ethyl Chloride Spray After Use in the Clinic
Kristin Sandrowski1, Jack Graham2, Samantha Knott1
1Thomas Jefferson University, Philadelphia, PA, USA.
Abstract:
Background: Ethyl chloride spray is used frequently in the outpatient setting as a local anesthetic for injections and aspirations with varying consensus about the sterility of the spray. We hypothesize that ethyl chloride spray remains sterile and would show no bacterial growth during routine clinical use. Methods: Thirteen ethyl chloride bottles were collected for testing. Two unopened bottles were used as controls. Eleven unopened bottles were placed in orthopedic clinics and recollected after varying duration of use. The final volume and duration of use were recorded. Each bottle was sprayed in a separate test tube and allowed to evaporate. Trypticase soy broth was added to each tube and incubated for 48 hours. Control test tubes with broth alone were prepared and incubated under the same conditions. Cultures were evaluated at 24 and 48 hours. Results: The mean duration of ethyl chloride bottle use prior to culturing was 26 days. The average volume used per day was 1.9 mL. Each ethyl chloride bottle had an initial volume of 103.5 mL. Using the average daily volume usage, an extrapolated lifespan of each bottle was estimated at 7.7 weeks. None of the samples showed bacterial or fungal growth at 24 or 48 hours. Conclusion: Ethyl chloride bottles used in the clinical settings showed no bacterial or fungal contamination through their shelf life and routine use. The duration and amount of use did not affect sterility. Although the antimicrobial activity of ethyl chloride spray on skin is debated, ethyl chloride itself remains sterile through clinical use.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Roles of Electrolytes: Chloride and Bicarbonate
Conditions such as hypochloremia can arise from insufficient chloride reabsorption by the kidneys, often compounded by extended bouts of diarrhea, vomiting,...
Carboxylic Acids to Acid Chlorides
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:

