Assessment of Adaptive Margins Using a Single Planning Computed Tomography Scan for Bladder Radiotherapy
Romel Canlas1, Nevin McVicar2, Sandy Nakano3
1Department of Radiation Therapy, Abbotsford Centre, BC Cancer Agency, Abbotsford, BC, Canada.
Introduction:
A "plan of the day" (PoD) adaptive radiotherapy approach is presented for bladder cancer. The potential reduction in volumes of normal tissue and bowel bag receiving high-dose radiation is evaluated.
Materials And Methods:
Planning computed tomography (pCT) and daily cone beam CT (CBCT) data sets were analyzed for eight previously treated bladder cancer patients. For each patient, a whole bladder clinical target volume (CTV) was delineated on a pCT. Then, the clinical target volume was expanded using five sets of anisotropic or isotropic margins to create five planning target volumes (PTVs). A library of five corresponding treatment PoDs was then created using volumetric modulated arc therapy. Offline PoD selection was performed by three independent radiation therapists (RTs) using daily CBCTs. Dosimetric results were compared between PoD treatments and two conventional treatments using isotropic 1.5- and 2.0-cm margins.
Results:
The smallest PTV using 1.0-cm isotropic margins was selected most frequently (70%). Three RTs demonstrated good agreement for daily PTV selections, choosing identical PoDs for 51% of all CBCTs. In addition, acceptable dosimetric coverage of the whole bladder was achieved for all PoD selections, similar to standard treatments. The average volume of bowel bag receiving 45 and 50 Gy and normal tissue receiving 95% prescription dose was significantly (P < .01) lower for PoD treatments compared with both conventional treatments.
Conclusions:
A PoD strategy using one pCT with isotropic and anisotropic margins can be used to treat bladder cancer and improve sparing of the bowel bag. Minimal dosimetric differences observed between three RTs suggests that PoD strategies are feasible for clinical implementation.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Margin of Error
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Leaky Scanning