Related Experiment Video
Updated: Jan 25, 2026

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Anterior Atlanto-Occipital Transarticular Screw Fixation: A Radiological Evaluation
Xiaolin Xu1, Wei Ji1, Xiang Liu2
1Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Background:
In situations in which posterior atlanto-occipital fixation might not be possible or might require supplemental fixation, anterior fixation might add stability in obtaining arthrodesis. The present study aimed to provide a radiographic evaluation of the safety and feasibility in the anterior approach.
Methods:
The bilateral craniocervical computed tomography slices of 60 patients were examined. The anterior screw entry point was the lowest point at the middle anterior aspect of C1 (atlas) lateral mass. To avoid hypoglossal canal and craniocerebral injury, the height of the hypoglossal canal and occipital condyle and occipital condyle width were obtained. The mandible occlusion angle (MOA), anterior screw trajectory above, under, and distal to the hypoglossal canal (AHA, UHA, and DHA) relative to the tangent line of C1 front border were measured, together with the maximum screw length under each angle (AHL, UHL and DHL). An independent samples t test was used for statistical analysis.
Results:
The height of the hypoglossal canal and occipital condyle and occipital condyle width were all larger in the men than in the women. The MOA, AHA, UHA, and DHA were 55.0°, 18.7°, 41.0°, and 55.0°, respectively, and were similar between genders. The AHL, UHL, and DHL were 34.5, 30.9, and 31.3 mm, with the measurements for the men generally longer than those for the women by 3-4 mm. A total of 10 of 120 bilateral measurements showed the possibility of mandible occlusion, and the potential success rate of the anterior approach could reach 91.7%.
Conclusions:
The ideal entry angle for anterior atlanto-occipital fixation ranges from 41.0° to 55.0°, with a safe screw length from 30.9 to 31.3 mm. The potential success rate could reach >90%.
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Radiological Investigation I: X-ray and CT
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

