Related Experiment Video
Updated: Jan 25, 2026

Low-Cost Single-Port LoCoSP Device for a Transcervical Approach in Minimally Invasive Transhiatal Esophagectomy
Published on: September 11, 2021
A low-cost, non-invasive phase velocity and length meter and controller for multiphase lab-in-a-tube devices
Corwin B Kerr1, Robert W Epps, Milad Abolhasani
1Department of Chemical and Biomolecular Engineering, North Carolina State University, 911 Partners Way, Raleigh, USA. abolhasani@ncsu.edu.
Abstract:
Opportunities for accessible microfluidic device integration have sharply grown with the rise of readily available lab-in-a-tube strategies. Herein, we present a facile, non-invasive, plug-and-play phase velocity and length measuring strategy for rapid deployment onto tube-based microfluidic systems, enabling quick and accurate residence (reaction) time measurement and tuning. Our approach utilizes inexpensive off-the-shelf optical phase sensors and requires no prior knowledge of the fluid composition or physical properties. Compared to camera-based measurements in fluoropolymer tubing, the optical phase sensor-based technique shows mean absolute percentage errors of 1.3% for velocity and 3.3% for length. Utilizing the developed multiphase flow monitoring technique, we screen the accessible parameter space of gas-liquid segmented flows. To further demonstrate the functionality of this process monitoring strategy, we implement two feedback controllers to establish simultaneous setpoint control for phase velocity and length. Next, to showcase the effectiveness and versatility of the developed multiphase flow process controller, we apply it to systematic studies of the effect of liquid slug velocity (controlling precursor mixing timescale) on the colloidal synthesis of cesium lead tribromide nanocrystals. By varying the liquid slug velocity and maintaining constant precursor composition, liquid slug length, and residence time, we observe a bandgap tunability from 2.43 eV (510 nm) to 2.52 eV (494 nm).
Related Concept Videos
Phase-lead and Phase-lag Controllers
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Kinetic Molecular Theory: Molecular Velocities, Temperature, and Kinetic Energy
Average Velocity
Instantaneous Velocity - II

