Related Experiment Video
Updated: Jan 25, 2026

3D Printing - Evaluating Particle Emissions of a 3D Printing Pen
Published on: October 9, 2020
Assessment of body-powered 3D printed partial finger prostheses: a case study
Keaton J Young1, James E Pierce2, Jorge M Zuniga2,3
1Department of Biomechanics, University of Nebraska at Omaha, 6001 Dodge Street Omaha, Nebraska, NE, 68182, USA. keatonyoung@unomaha.edu.
Background:
Traditional prosthetic fabrication relies heavily on plaster casting and 3D models for the accurate production of prosthetics to allow patients to begin rehabilitation and participate in daily activities. Recent technological advancements allow for the use of 2D photographs to fabricate individualized prosthetics based on patient anthropometrics. Additive manufacturing (i.e. 3D printing) enhances the capability of prosthesis manufacturing by significantly increasing production speed and decreasing production cost. Existing literature has extensively described the validity of using computer-aided design and 3D printing for fabrication of upper limb prostheses. The present investigation provides a detailed description of the development of a patient specific body-powered 3D printed partial finger prosthesis and compares its qualitative and functional characteristics to a commercially available finger prosthesis.
Case Presentation:
A 72-year old white male with a partial finger amputation at the proximal interphalangeal joint of the left hand performed a simple gross motor task with two partial finger prostheses and completed two self-reported surveys (QUEST & OPUS). Remote fitting of the 3D printed partial finger began after receipt of 2D photographs of the patient's affected and non-affected limbs. Prosthetic fitting when using 3D printable materials permitted the use of thermoforming around the patient's residual limb, allowing for a comfortable but tight-fitting socket. Results of the investigation show improved performance in the Box and Block Test when using both prostheses (22 blocks per minute) as compared to when not using a prosthesis (18 blocks per minute). Both body-powered prostheses demonstrated slightly lower task-efficiency when compared to the non-affected limb (30 blocks per minute) for the gross motor task. Results of the QUEST and OPUS describe specific aspects of both prostheses that are highly relevant to quality of life and functional performance when using partial finger prostheses.
Conclusion:
The use of 3D printing exhibits great potential for the fabrication of functional partial finger prostheses that improve function in amputees. In addition, 3D printing provides an alternative means for patients located in underdeveloped or low-income areas to procure a functional finger prosthesis.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Power

