Luminescence Lifetime Imaging of O2 with a Frequency-Domain-Based Camera System
Published on: December 16, 2019
Quantification of forward scattering based on the analysis of double-pass images in the frequency domain
Joan A Martínez-Roda1, Carlos E García-Guerra1, Fernando Diaz-Doutón1
1Centre for Sensors, Instruments and Systems Development (CD6), Universitat Politècnica de Catalunya (UPC), Terrassa, Spain.
Purpose:
To assess forward intraocular scattering by means of a new parameter (Frequency Scatter Index, FSI3 ) based on the analysing double-pass retinal images in the frequency domain, which minimizes the impact of aberrations on the results.
Methods:
A prospective observational study was carried out in the Department of Ophthalmology, Hospital Universitari Mútua de Terrassa (Spain) on a group of 19 patients diagnosed with nuclear cataracts of various LOCSIII grades and a control group (CG) with nine healthy eyes. We recorded double-pass retinal images with a custom set-up based on a high-sensitivity digital camera. The FSI3 was then computed using spatial frequencies below three cycles per degree. A preliminary validation of the FSI3 was performed on an artificial eye and two eyes of volunteers with and without commercial diffusers, and under defocus.
Results:
The FSI3 was hardly affected by defocus values up to 2.50 D. The mean (and standard deviation) FSI3 values were as follows: for the CG, 1.19 (0.21); and for LOCSIII grades nuclear opacity 1, 2 and 3, 1.30 (0.12), 1.62 (0.21) and 1.85 (0.21), respectively. Eyes with cataracts showed FSI3 values significantly different than healthy eyes (p = 0.001). A good correlation (ρ = 0.861, p < 0.001) was found between the FSI3 and objective scatter index provided by a commercial instrument.
Conclusion:
Since aberrations have little impact on the FSI3 , the light scatter assessment becomes less dependent on the patient's refractive error compensation and the presence of higher-order aberrations. The FSI3 can further the clinical and scientific understanding of forward intraocular scattering.
Related Concept Videos
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
First Pass Effect
Depending on the route of administration, drugs can be metabolized in the liver, intestine, lungs, and vasculature. Orally administered drugs are first absorbed through the...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...