Thermal Conductivity Enhancement in MoS_{2} under Extreme Strain
Xianghai Meng1, Tribhuwan Pandey2, Jihoon Jeong1
1Department of Mechanical Engineering, The University of Texas at Austin, 204 E. Dean Keeton Street, Austin, Texas 78712, USA.
Abstract:
Because of their weak interlayer bonding, van der Waals (vdW) solids are very sensitive to external stimuli such as strain. Experimental studies of strain tuning of thermal properties in vdW solids have not yet been reported. Under ∼9% cross-plane compressive strain created by hydrostatic pressure in a diamond anvil cell, we observed an increase of cross-plane thermal conductivity in bulk MoS_{2} from 3.5 to about 25 W m^{-1} K^{-1}, measured with a picosecond transient thermoreflectance technique. First-principles calculations and coherent phonon spectroscopy experiments reveal that this drastic change arises from the strain-enhanced interlayer interaction, heavily modified phonon dispersions, and decrease in phonon lifetimes due to the unbundling effect along the cross-plane direction. The contribution from the change of electronic thermal conductivity is negligible. Our results suggest possible parallel tuning of structural, thermal, and electrical properties of vdW solids with strain in multiphysics devices.
More Related Videos
10:01Thermal Scanning Conductometry TSC as a General Method for Studying and Controlling the Phase Behavior of Conductive Physical Gels
Published on: January 23, 2018
08:00Chemical Synthesis of Porous Barium Titanate Thin Film and Thermal Stabilization of Ferroelectric Phase by Porosity-Induced Strain
Published on: March 27, 2018
Related Concept Videos
Thermal Strain
Self-Evaluation: Self-Enhancement and Self-Verification
Absolute and Local Extreme Values
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Conduct Disorder
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...