Inversion of displacement fields to quantify the magnetic particle distribution in homogeneous elastic media from
Diwash Thapa1, Benjamin E Levy1, Daniel L Marks2
1Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, United States of America.
Abstract:
Magnetomotive ultrasound (MMUS) contrasts superparamagnetic iron-oxide nanoparticles (SPIOs) that undergo submicrometer-scale displacements in response to a magnetic gradient force applied to an imaging sample. Typically, MMUS signals are defined in a way that is proportional to the medium displacement, rendering an indirect measure of the density distribution of SPIOs embedded within. Displacement-based MMUS, however, suffers from 'halo effects' that extend into regions without SPIOs due to their inherent mechanical coupling with the medium. To reduce such effects and to provide a more accurate representation of the SPIO density distribution, we propose a model-based inversion of MMUS displacement fields by reconstructing the body force distribution. Displacement fields are modelled using the static Navier-Cauchy equation for linear, homogeneous, and isotropic media, and the body force fields are, in turn, reconstructed by minimizing a regularized least-squares error functional between the modelled and the measured displacement fields. This reconstruction, when performed on displacement fields of two tissue-mimicking phantoms with cuboidal SPIO-laden inclusions, improved the range of errors in measured heights and widths of the inclusions from 54%-282% pre-inversion to-15%-20%. Likewise, the post-inversion contrast to noise ratios (CNRs) of the images were significantly larger than displacement-derived CNRs alone (p = 0.0078, Wilcoxon signed rank test). Qualitatively, it was found that inversion ameliorates halo effects and increases overall detectability of the inclusion. These findings highlight the utility of model-based inversion as a tool for both signal processing and accurate characterization of the number density distribution of SPIOs in magnetomotive imaging.
Related Concept Videos
Motion Of A Charged Particle In A Magnetic Field
Elastic Curve from the Load Distribution
For all beams, the analysis of the beam's reaction to distributed loads begins by understanding the relationship between a beam's load and the resulting shear forces and bending moments. Initially, this...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...


