A Retrospective Analysis of Prostate Cone Beam Computed Tomography (CBCT) Image Registration: A Tale of Two
Brian Liszewski1, Enoch Choo2, Laura D'Alimonte1
1Radiation Therapy, Department of Radiation Therapy, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
Purpose:
To determine the feasibility of the gray-value registration technique as a correction method for prostate image-guided radiotherapy.
Background:
The current practice at this institution involves a two-step process beginning with an automated bone registration, followed by a manual therapist manipulated registration.
Problem:
This process is susceptible to subjective judgement and inter-observer variability, which introduces inconsistencies in image registrations and subsequent treatment delivery. Variation in the time required to complete image registrations may increase the chance for prostate intra-fractional movement, which may increase treatment inaccuracies.
Methods:
A retrospective image review was completed for 20 patients. Translational shifts and duration data for therapist registrations were retrieved for 15 scans for each patient, totaling 300 scans. Gray-value registrations were completed on the same 300 scans to recalculate shift values and the time to complete this technique was recorded. The analysis of variance test was used to analyze the extent of variance between the two registration techniques.
Results:
No difference between the two registration techniques in the lateral (right-left) direction (P = .364) and superoinferior directions (P = .455) were found. Gray-value registrations took significantly less time to complete and were more consistent than the two-step therapist registrations (P < .001). A statistically significant difference in z shifts exists (P = .003) between the two techniques.
Conclusion:
Gray-value registration can minimize and standardize the image registration durations and produce x and y shifts similar to those produced by therapists. Lacking the ability to preferentially match to the prostate-rectum interface, therapists still need to perform a simple inspection in the z (anteroposterior) plane to ensure an adequate registration to the interface.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...