An Analysis of Inter-Operator Registration Variability in Helical Tomotherapy
David Cooper1, Mehdi Saberi2, Eduardo Galiano3
1Radiation Therapy Department, The Ottawa Hospital Cancer Centre, Ottawa, Ontario.
Abstract:
This study aims to determine the image registration interoperator variability using the image fusion interface on the TomoTherapy system. The study focused on the registration results among five Ottawa Hospital Cancer Centre personnel comparing 15 retrospective prostate, bladder, and head and neck patients from day 2 megavoltage computed tomography images with planning computed tomography images. Personnel were instructed to manually adjust the fused images after automatic bony registration matching disease-specific criteria. The Pearson correlation matrix was applied to the summed vector lengths of the personnel's overall translations in all three disease sites. The results were compared with a chosen benchmark personnel and were analyzed for significance in correlation. Finally, the overall translations compared with the automatic bony registration were analyzed for any trends in the data. In each disease site, the average correlation from all personnel compared to a benchmark registering prostate, bladder, and head and neck patients were 0.94, 0.94, and 0.64, respectively. Then, analysis of the interuser overall translations illustrated that each disease site had its own trends with regard to interfraction image fusion corrections. Finally, the mean translational variations were assessed over all personnel for each disease site in X (lateral), Y (longitudinal), and Z (vertical) directional planes. The results demonstrate that consistent, accurate image registration is dependent on factors involving overall user experience with TomoTherapy software and user knowledge of human sectional anatomy, among others.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Variables Affecting Phosphorescence and Fluorescence
Work and Energy for Variable Forces
Operational Amplifiers
Vector Operations
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.