The Effect of Dose Grid Resolution on Dose Volume Histograms for Slender Organs at Risk during Pelvic
Tara Rosewall1, Vickie Kong2, Robert Heaton3
1Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Canada; Charles Sturt University, New South Wales, Australia.
Purpose:
There are enduring uncertainties regarding the optimal dose grid resolution for use with pelvic intensity-modulated radiotherapy (IMRT) plans in which the adjacent organs at risk are slender and transect the field edge. Therefore, this study evaluated the effect of dose grid resolution on bladder wall dose-volume histogram (DVH) calculations for prostate IMRT plans.
Materials And Methods:
The planning computed tomography scans and clinical plans from 15 prostate cancer patients were included in this analysis. For each study computed tomography, the entire inner and outer bladder surfaces were delineated. Nine versions of the clinical plan were created, varying interval between the dose grid calculation points uniformly in three dimensions, whereas all other plan parameters were kept constant. The dose grid increments tested were 1-10 mm. The plans were recalculated and the bladder wall DVH compared against the study benchmark (1 mm grid).
Results:
All the dose grid increments evaluated resulted in a systematic overestimation of the bladder wall volume receiving low doses and an underestimation of the volume receiving high doses. Grid increments <2.5 mm all resulted in mean volume differences less than 1 cm3 across the whole DVH. Grid increments >5.0 mm resulted in mean volume differences greater than 2 cm3. Individual patient analysis revealed that only the 1.5 mm increment resulted in maximum volume differences ≤1 cm3 for every patient across the full length of the DVH curve. Bladder wall thickness ranged from 1.7 to 4.4 mm and displayed no correlation with the magnitude of the dose grid effect.
Conclusions:
For an accurate DVH calculation for bladder wall during IMRT planning for prostate cancer, a 1.5 mm dose grid increment is recommended. This finding was unaffected by a normal range in bladder wall thickness. It is suggested that the application of any new treatment planning technique or organ delineation method be accompanied with an evaluation of optimal dose grid resolution.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dose-Response Relationship: Overview
Drug Dosing: Infants and Children
Drug Dosing: Geriatric Patients