Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

9.2K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.2K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

241
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
241
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

1.2K
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Nuclear Magnetic Resonance (NMR): Overview01:07

Nuclear Magnetic Resonance (NMR): Overview

6.8K
Nuclear magnetic resonance (NMR) is a phenomenon exhibited by certain nuclei that can absorb characteristic radio frequency radiation under certain conditions. NMR has been extensively applied in molecular spectroscopy and medical diagnostic imaging. In both these applications, the molecule or subject under study is placed in a magnetic field and irradiated with radio frequency energy.
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
6.8K
Resonance02:52

Resonance

64.9K
The Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N-O and N=O bonds.
64.9K
Knee Joint01:23

Knee Joint

3.1K
The knee joint is the most complicated joint in the body. It consists of three articulations– two tibiofemoral and one patellofemoral. As is characteristic of synovial joints, the knee joint has a thin articular capsule that partially surrounds this joint cavity. Additionally, several ligaments, muscles, and cartilaginous structures support the movement of the knee.
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
3.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Block Matching Based Speckle Tracking Echocardiography: Clinical Applications and Research Outlook in a Deep Learning Context.

Journal of imaging informatics in medicine·2025
Same author

Diffusion Meets Sinogram: A Hybrid Learning Framework for Low-Dose CT Image Denoising with Structural and Textural Priors.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

GEDFormer: Gradient Edge Detection in LDCT Image Denoising Transformer Model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

SGAMARN: A GAN Framework for Metal Artifact Reduction in CT Imaging.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

Point-of-care musculoskeletal ultrasound for hemophilic arthropathy: a scoping review of scanning protocols by the Imaging Expert Working Group of the International Prophylaxis Study Group.

Research and practice in thrombosis and haemostasis·2025
Same author

Recommendations Regarding the Appropriateness of Virtual Care: A Systematic Review.

Telemedicine journal and e-health : the official journal of the American Telemedicine Association·2025

Related Experiment Video

Updated: Jan 25, 2026

Multiple-mouse Neuroanatomical Magnetic Resonance Imaging
09:08

Multiple-mouse Neuroanatomical Magnetic Resonance Imaging

Published on: February 27, 2011

16.4K

Effect of Day Optimizing Throughput (Dot) Knee Software Implementation on Magnetic Resonance Imaging Workflow

Shawn Kisch1, Paul Babyn1, Chris Plewes1

  • 1The Department of Medical Imaging, University of Saskatchewan and Saskatoon Health Region, Saskatoon, SK, Canada.

Journal of Medical Imaging and Radiation Sciences
|May 5, 2019
PubMed
Summary

Automated knee MRI software offers standardized protocols but provides minimal time savings. The high implementation cost and limited efficiency gains make a financial return unlikely for most imaging centers.

Keywords:
automation softwareimage alignmentknee MRIprotocol standardizationscan efficiency

More Related Videos

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

20.1K
Hyperpolarized 13C Metabolic Magnetic Resonance Spectroscopy and Imaging
11:43

Hyperpolarized 13C Metabolic Magnetic Resonance Spectroscopy and Imaging

Published on: December 30, 2016

11.0K

Related Experiment Videos

Last Updated: Jan 25, 2026

Multiple-mouse Neuroanatomical Magnetic Resonance Imaging
09:08

Multiple-mouse Neuroanatomical Magnetic Resonance Imaging

Published on: February 27, 2011

16.4K
Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

20.1K
Hyperpolarized 13C Metabolic Magnetic Resonance Spectroscopy and Imaging
11:43

Hyperpolarized 13C Metabolic Magnetic Resonance Spectroscopy and Imaging

Published on: December 30, 2016

11.0K

Area of Science:

  • Medical Imaging
  • Radiology
  • Magnetic Resonance Imaging (MRI)

Background:

  • Automated MRI software aims to improve patient throughput and standardize imaging protocols.
  • Significant investment is required for implementing new automated systems, potentially limiting adoption.

Purpose of the Study:

  • To assess the implementation costs of automated knee MRI software.
  • To evaluate the reduction in examination durations with automated knee MRI software.
  • To determine the return on investment for automated knee MRI systems.

Main Methods:

  • A 3-Tesla MRI system at an academic center used Siemens' Dot knee software.
  • Acquisition times were compared before and after software implementation.
  • Costs of implementation and MRI utilization were analyzed to calculate the break-even point.

Main Results:

  • Automated software resulted in a mean time saving of 64 seconds per knee examination.
  • Routine knee scans decreased from 23.20 to 21.94 minutes; fast scans from 11.88 to 11.24 minutes.
  • The software simplified 29 protocols to two, enhancing consistency but facing compatibility limitations.

Conclusions:

  • Automated knee MRI systems can standardize protocols but offer negligible time savings.
  • High implementation costs and minimal efficiency gains make financial returns unlikely for small- to medium-sized institutions.
  • Compatibility issues and scheduling challenges limit the clinical utility of current automated systems.