Loss of 1p36.33 Frequent in Low-Grade Serous Ovarian Cancer

Els Van Nieuwenhuysen1, Pieter Busschaert2, Annouschka Laenen3

  • 1Department of Obstetrics and Gynecology, University Hospitals Leuven, Leuven, Belgium; Division of Gynaecological Oncology, Leuven Cancer Institute, Kuleuven, Leuven, Belgium.

Neoplasia (New York, N.Y.)
|May 5, 2019
PubMed
Abstract

Related Concept Videos

Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
520
Graded Potential01:19

Graded Potential

Graded potentials are localized fluctuations in the cell membrane's electrical charge, commonly found in the dendrites of neurons. The magnitude of these potential changes depends on the strength of the initiating stimulus. In a membrane at its resting potential, a graded potential signifies a voltage shift either above -70 mV or below -70 mV.
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
6.9K
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
372
Types of Aggregate Grading01:15

Types of Aggregate Grading

Aggregate grading is crucial in economically obtaining a concrete mix with adequate strength, reasonable workability, and minimal segregation. There are four types of aggregate gradation: well-graded, uniformly (or one-sized) graded, gap-graded, and open-graded.
Well-graded aggregates include a complete range of necessary size fractions that fit together to create a dense matrix with minimal voids, represented by a smooth, continuous gradation curve. This type of grading ensures good...
1.4K
Major Losses in Pipes01:28

Major Losses in Pipes

When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
1.9K
Minor Losses in Pipes01:25

Minor Losses in Pipes

In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
1.9K