Comprehensive Evaluation of Retinal Image Quality in Comparing Different Aspheric to Spherical Intraocular Lens
Xuan Liao1, Xiuqi Haung1, Changjun Lan1
1Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College , Nanchong , Sichuan Province , China.
Abstract:
Purpose: To compare the visual and optical quality of eyes implanted with three aspheric versus two spherical intraocular lenses (IOL) after cataract surgery. Methods: This prospective comparative study included 349 eyes of 349 patients with age-related cataract and undergone uneventful phacoemulsification. Implanted posterior monofocal IOLs have an aspheric optic (Tecnis ZCB00 [Johnson & Johnson Vision], Acrysof IQ SN60WF [Alcon], Akreos AO [Bausch & Lomb]) or a spherical optic (Akreos [Bausch & Lomb], Sensar AR40e [Johnson & Johnson Vision]). Postoperatively, objective optical quality parameters were performed using an Optical Quality Analysis System II (Visiometrics), and wave-front aberrations were assessed using a KR-1W aberrometer (Topcon). Meanwhile, subjective visual acuity was performed using a logarithm of the minimum angle of resolution chart at 3 months after cataract surgery. Results: Statistical significant differences (P < .05) across all groups were found regarding intraocular and total ocular spherical aberration (SA) at 4.0 mm and 6.0 mm pupil diameter and total high-order aberration (tHOA) at 6.0 mm pupil diameter. Furthermore, differences among the evaluated groups were observed regarding several objective parameters such as objective scatter index (OSI), modulation transfer function cutoff (MTF cutoff), Strehl ratio (SR) at two dimensions and contrast visual acuity (OV) at three contrast levels. Conclusions: The present results reflect the optical characteristics of IOL in vivo. The scattering light and high-order aberration may be the main reasons for the degradation of retinal imaging quality in comparing different aspheric to spherical IOL implants.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
10:00Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
Published on: February 14, 2015
Related Concept Videos
Spherical Coordinates
Spherical and Cylindrical Capacitor
Conventionally, considering the symmetry, the electric field between the concentric shells of a spherical capacitor is directed radially outward. The magnitude of the field,...
Gravity between Spherical Bodies
This assumption can be proved easily by showing that the expression for gravitational potential energy between a hollow sphere of mass (M) and a point mass (m) is the same as it would be for a pair of extended...
Gravitation Between Spherically Symmetric Masses
Gauss's Law: Spherical Symmetry
Comparing Intermolecular Forces: Melting Point, Boiling Point, and Miscibility
Temporary attractive forces like dispersion are present in all molecules, whether they are polar or nonpolar. They...