An Alternative to the Traditional Cold Pressor Test: The Cold Pressor Arm Wrap
Published on: January 16, 2014
Human Responses to 5 Heated Hypothermia Wrap Systems in a Cold Environment
Ramesh Dutta1, Kartik Kulkarni1, Alan M Steinman2
1Laboratory for Exercise and Environmental Medicine, Faculty of Kinesiology and Recreation Management, University of Manitoba, Winnipeg, Canada.
The user-assembled and Doctor Down heated hypothermia wrap systems were most effective in preventing heat loss during extreme cold exposure. While all systems may be viable, these two demonstrated superior performance in maintaining body heat.
Area of Science:
- Environmental Physiology
- Thermoregulation Research
- Wilderness Medicine Equipment
Background:
- Hypothermia poses a significant risk in cold environments.
- Effective thermal management systems are crucial for preventing hypothermia.
- Evaluating the efficacy of heated hypothermia wraps is essential for outdoor safety.
Purpose of the Study:
- To compare the effectiveness of five different heated hypothermia wrap systems.
- To assess both physiological and subjective responses to these systems under extreme cold conditions.
- To identify the most effective heated wrap systems for preventing hypothermia.
Main Methods:
- Five heated hypothermia wrap systems were tested on five normothermic subjects.
- Subjects were exposed to -22°C for 60 minutes with vapor barriers and chemical heat sources.
- Core and skin temperatures, metabolic heat production, heat loss, and net heat gain were measured, alongside subjective responses.
Main Results:
- The Doctor Down Rescue Wrap and user-assembled systems showed higher skin temperatures and net heat gain, with less heat loss.
- These two systems also exhibited lower metabolic heat production compared to others.
- The hypothermia prevention and management kit (HPMK) resulted in the lowest skin temperature and highest shivering, with poor subjective ratings.
Conclusions:
- User-assembled and Doctor Down systems were the most effective in maintaining body heat.
- The hypothermia prevention and management kit (HPMK) was the least effective, leading to the coldest subjective experience.
- All systems may be viable for wilderness responders, with selection dependent on cost, size, and weight.
More Related Videos
08:22In vitro Assessment of Myocardial Protection following Hypothermia-Preconditioning in a Human Cardiac Myocytes Model
Published on: October 27, 2020
05:00Short-Duration Hypothermia Induction in Rats using Models for Studies examining Clinical Relevance and Mechanisms
Published on: March 3, 2021
Related Concept Videos
Responses to Heat and Cold Stress
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Quantifying Heat
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Heat Flow and Specific Heat
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...