Related Experiment Video
Updated: Jan 25, 2026

Application of Hemostatic Devices in Laparoscopic Hepatectomy
Published on: April 19, 2022
Evaluation of a Chitosan Hemostat in a Porcine Laparoscopic Partial Nephrectomy Model: A Pilot Study
Andrew Crofton1,2,3, Duane Baldwin4, Muhannad Alsyouf4
1Department of Anatomy, School of Medicine, Case Western Reserve University, Cleveland, Ohio.
Abstract:
The ideal hemostatic agent for laparoscopic partial nephrectomy (LPN) would provide complete hemostasis and sealing of the collecting system at a low cost. Chitosan (CS) is an established topical hemostatic agent, but standard sterilization techniques affect its functional and biologic properties, thereby preventing parenteral uses. This study sought to characterize the safety and efficacy of an implanted CS hemostat sterilized with either a standard technique, electron beam (e-beam) irradiation, or a novel technique, nonthermal nitrogen plasma, in a porcine LPN model. Laparoscopic partial nephrectomies were performed on six farm pigs and hemostasis achieved using only a CS hemostatic agent (Clo-Sur P.A.D.) that was e-beam (n = 3) or plasma sterilized (PS) (n = 3). Number of pads needed to achieve hemostasis, estimated blood loss, operative time, mass of kidney resection, and warm ischemia time were measured. Animals were monitored for 14 weeks and at harvest, retrograde ureteropyelography and histologic analysis were performed. Complete hemostasis and collection system sealing were achieved in both groups. There was a trend toward less pads required for hemostasis (p = 0.056) and reduced blood loss (p = 0.096) with PS pads, although this did not achieve statistical significance. No complications were observed for 14 weeks and gross examination showed the implanted CS was encapsulated in a fibrous capsule. Histologic analysis revealed a healed nephrectomy site with residual CS and associated chronic inflammation, reactive fibrosis, and foreign body giant cell formation. Importantly, the adjacent renal tissue was intact and viable with no residual parenchymal inflammation or cytologic damage. CS pads alone provided safe and effective hemostasis in a porcine LPN model. PS may enhance hemostatic efficacy and resorption compared with e-beam.
Related Concept Videos
Pilot and Numeric Relaying
Self-Evaluation Maintenance Model
Mixtures of Gases: Dalton's Law of Partial Pressures and Mole Fractions
Dalton's Law of Partial Pressure
Dosage Regimens: Partial Pharmacokinetic Parameters
Inverse z-Transform by Partial Fraction Expansion
To begin the process, the poles of the function are identified and the function is...

