Related Experiment Video
Updated: Jan 25, 2026

Echocardiographic Measurement of Right Ventricular Diastolic Parameters in Mouse
Published on: April 27, 2019
Elevated soluble-St2 concentrations in preeclampsia correlate with echocardiographic parameters of diastolic
Sara Mugerli1, Jana Ambrožič2, Ksenija Geršak3
1Department of Perinatology, Division of Obstetrics and Gynecology, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Objectives: To compare soluble-ST2 (sST2) concentrations in patients with severe features of preeclampsia and healthy pregnant controls before as well as 1 year after delivery. Another objective was to assess potential correlation between sST2 concentrations and myocardial function.Methods: Patients with singleton pregnancy complicated by severe features of preeclampsia and healthy controls were included in a prospective observational study. Plasma sST2 concentrations were measured within 24 h before delivery and 1 year after delivery. Standard two-dimensional and Doppler echocardiography was performed at the time of first sST2 measurement before delivery. Mann-Whitney U test was used to compare sST2 values in preeclamptic patients versus controls. Kendall's tau was used to assess correlation between sST2 values and echocardiographic measures of left ventricular systolic and diastolic function (p < .05 significant).Results: We included 24 patients with severe preeclampsia and 29 controls. One year after delivery, sST2 concentrations were available for 24 (45%) participants (13 in preeclampsia group and 11 controls). Concentrations of sST2 were markedly elevated in patients with severe preeclampsia compared to healthy controls before delivery (p = .04), but not 1 year after delivery (p = .80). There was no significant correlation between sST2 and parameters of systolic function. In preeclamptic patients, we found a significant inverse correlation between sST2 and markers of diastolic function: peak early mitral inflow velocity E (Kendall's tau = -0.40; p = .02), peak early diastolic myocardial velocities at septal and lateral mitral annulus (e') (Kendall's tau = -0.354, p = .04) and ratio between e' and peak systolic myocardial velocities at the septal and lateral mitral annulus (e'/s') (Kendall's tau = -0.362, p = .04).Conclusions: Preeclampsia with severe features is associated with increased maternal plasma concentrations of sST2, which return to normal values in the first year after delivery. Higher sST2 levels in preeclamptic patients correlate with impaired parameters of left ventricular diastolic function.
Objectives: To compare soluble-ST2 (sST2) concentrations in patients with severe features of preeclampsia and healthy pregnant controls before as well as 1 year after delivery. Another objective was to assess potential correlation between sST2 concentrations and myocardial function.Methods: Patients with singleton pregnancy complicated by severe features of preeclampsia and healthy controls were included in a prospective observational study. Plasma sST2 concentrations were measured within 24 h before delivery and 1 year after delivery. Standard two-dimensional and Doppler echocardiography was performed at the time of first sST2 measurement before delivery. Mann-Whitney U test was used to compare sST2 values in preeclamptic patients versus controls. Kendall's tau was used to assess correlation between sST2 values and echocardiographic measures of left ventricular systolic and diastolic function (p < .05 significant).Results: We included 24 patients with severe preeclampsia and 29 controls. One year after delivery, sST2 concentrations were available for 24 (45%) participants (13 in preeclampsia group and 11 controls). Concentrations of sST2 were markedly elevated in patients with severe preeclampsia compared to healthy controls before delivery (p = .04), but not 1 year after delivery (p = .80). There was no significant correlation between sST2 and parameters of systolic function. In preeclamptic patients, we found a significant inverse correlation between sST2 and markers of diastolic function: peak early mitral inflow velocity E (Kendall's tau = -0.40; p = .02), peak early diastolic myocardial velocities at septal and lateral mitral annulus (e') (Kendall's tau = -0.354, p = .04) and ratio between e' and peak systolic myocardial velocities at the septal and lateral mitral annulus (e'/s') (Kendall's tau = -0.362, p = .04).Conclusions: Preeclampsia with severe features is associated with increased maternal plasma concentrations of sST2, which return to normal values in the first year after delivery. Higher sST2 levels in preeclamptic patients correlate with impaired parameters of left ventricular diastolic function.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
07:41Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Solubility Equilibria
The...
Factors Affecting Solubility
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Solubility of Ionic Compounds
Biodiversity and Human Values