Scalable fabrication of microneedle arrays via spatially controlled UV exposure
Hidetoshi Takahashi1, Yun Jung Heo2, Nobuchika Arakawa2
1Department of Mechano-Informatics, Graduate School of Information Science and Technology, the University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
Abstract:
This paper describes a theoretical estimation of the geometry of negative epoxy-resist microneedles prepared via inclined/rotated ultraviolet (UV) lithography based on spatially controlled UV exposure doses. In comparison with other methods based on UV lithography, the present method can create microneedle structures with high scalability. When negative photoresist is exposed to inclined/rotated UV through circular mask patterns, a three-dimensional, needle-shaped distribution of the exposure dose forms in the irradiated region. Controlling the inclination angles and the exposure dose modifies the photo-polymerized portion of the photoresist, thus allowing the variation of the heights and contours of microneedles formed by using the same mask patterns. In an experimental study, the dimensions of the fabricated needles agreed well with the theoretical predictions for varying inclination angles and exposure doses. These results demonstrate that our theoretical approach can provide a simple route for fabricating microneedles with on-demand geometry. The fabricated microneedles can be used as solid microneedles or as a mold master for dissolving microneedles, thus simplifying the microneedle fabrication process. We envision that this method can improve fabrication accuracy and reduce fabrication cost and time, thereby facilitating the practical applications of microneedle-based drug delivery technology.
Related Concept Videos
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
UV–Vis Spectrometers
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in...
UV–Vis Spectroscopy: Woodward–Fieser Rules