Related Experiment Video
Updated: Jan 25, 2026

Optic Nerve Sheath Point of Care Ultrasound: Image Acquisition
Published on: August 18, 2023
Optic Nerve Sheath Diameter Correlation with Elevated Intracranial Pressure Determined via Ultrasound
Kamran Munawar1, Muhammad Tariq Khan1, Syed Waqar Hussain2
1Internal Medicine, Shifa International Hospital, Islamabad, PAK.
Abstract:
Background The early detection of elevated intracranial pressure (ICP) can not only prevent mortality but also aid in more aggressive management. Brain computed tomography (CT) is a mainstay modality in detecting elevated ICP, but the feasibility of using brain CTs to detect elevated ICP in critically ill patients is limited, especially for patients who require high levels of inotropic support. The optic nerve sheath is a direct extension of the brain meninges. Therefore, the elevation of ICP is directly transmitted to the sheath. Measuring the optic nerve sheath diameter (ONSD) through ultrasound (US) is a bedside, noninvasive means to detect elevated ICP. The goal of this study was to assess the correlation of ONSD with elevated ICP as measured via US in an intensive care unit (ICU). Methods We conducted a six-month prospective, single-center, observational study of mass effect stroke patients aged 18 to 65 years who had a traumatic brain injury (TBI) and were admitted to the ICU. Patients with chronic hydrocephalus, extensive local orbit trauma, a pre-existing ocular disease affecting the optic nerve and/or orbital cavity, hyperthyroidism with exophthalmos, and facial trauma affecting the orbits and/or eyeballs were excluded. We measured the ONSD at the entry of optic nerve into the globe using two-dimensional (2D) US. Results One hundred patients were included in the study. Forty-nine patients had diffuse cerebral edema detected on CT scan correlating with increased ONSD notable via bedside US. The mean ONSD related to CT-detectable elevated ICP was 0.61 cm. The sensitivity for the ONSD cut-off value of ≥5.8 mm was 94% (95% confidence interval [CI], 84.05% to 98.79%), and the specificity was 96.08% (95% CI, 86.7% to 99.52%).The positive predictive value was 92.08% (95% CI, 86.28% to 98.96%), and the negative predictive value was 94.23% (95% CI, 84.47% to 98.00%). Conclusion The greatest accuracy in ONSD was found with a cut-off of >0.58 cm in patients with positive CT brain findings. Therefore, US can be used as an initial screening test when physicians suspect a patient has elevated ICP.
Related Concept Videos
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Correlations
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:
Elevation of Intermediate Points on Vertical Curves

