Related Experiment Video
Updated: Jan 25, 2026

Experimental Model of Ligature-Induced Peri-Implantitis in Mice
Published on: May 17, 2024
Periodic Assessment of Peri-implant Tissue Changes: Imperative for Implant Success
Shaifulizan Ab Rahman1, Hazelina Muhammad2, Sanjida Haque3
1Department of Oral Surgery and Maxillofacial Surgery, School of Dental Science, Universiti Sains Malaysia. Kubang Kerian, Kota Bharu, Kelantan, Malaysia, Phone: +609-7675821,
Aim:
The aim of this study was to evaluate the changes in the peri-implant hard and soft tissues and implant stability and to assess the correlation of bone loss and peri-implant probing depth with implant stability.
Materials And Methods:
Twenty-one patients with implants were included in this study and implants were assessed by resonance frequency analysis (RFA). Bone levels of the implants were assessed by measuring mesial and distal bone levels from the periapical radiograph, and soft tissue was assessed from probing depth using a periodontal probe. Implants were assessed for stability and probing depth at pre-loading, at 3 months and 6 months post-loading. RFA and probing depth were statistically compared from different time points. Correlation of probing depth and marginal bone loss with implant stability was also determined.
Results:
The average change in implant stability quotient (ISQ) measurements from pre-loading to 6 months post-loading was found to be statistically significant (p <0.005). The average probing depth reduced from 1.767 mm at pre-loading to 1.671 mm at post-loading 3 months, and 1.600 mm at post-loading 6 months. At 6 months of function, radiographic examination yielded 0.786 mm mesial bone loss and 0.8 mm distal bone loss. It was found to be statistically significant (p <0.005) but within an acceptable range. No significant correlation was found between implant stability and bone loss; and implant stability and probing depth.
Conclusion:
The study revealed an increasing trend in implant stability values with the time that indicates successful osseointegration. Increasing mean values for mesial and distal bone loss were also found.
Clinical Significance:
The success of dental implants is highly dependent on the quality of bone and implant-bone interface, i.e., osseointegration. The most important factors that influence the survival rate of an implant is initial stability. The present study found the changes in the peri-implant hard and soft tissues and implant stability. This article, while being a prospective study, may show the evidence of successful osseointegration by increasing trend in implant stability (RFA) values with time which can help to the clinician in the long-term management of implants.
Related Concept Videos
Ecological Succession
The Periodic Table
Periodic Classification of the Elements
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
The Periodic Table and Organismal Elements
The Periodic Table and Organismal Elements
Periodic Table Provides Information...