Related Experiment Video
Updated: Jan 25, 2026

Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis
Published on: December 16, 2016
Biofilm-enhanced adsorption of strong and weak cations onto different microplastic sample types: Use of spectroscopy,
Mathew P Johansen1, Tom Cresswell1, Joel Davis1
1Australian Nuclear Science and Technology Organisation (ANSTO), Locked Bag 2001, Kirrawee DC, NSW, 2232, Australia.
Abstract:
The adsorption of metals and other elements onto environmental plastics has been previously quantified and is known to be enhanced by surface-weathering and development of biofilms. However, further biofilm-adsorption characterisation is needed with respect to the fate of radionuclides. This study uses spectroscopy, microscopy and radiotracer methods to investigate the adsorption capacity of relatively strong and weak cations onto different microplastic sample types that were conditioned in freshwater, estuarine and marine conditions although marine data were limited. Fourier-transform infrared spectroscopy confirmed that surface oxidation chemistry changes induced by gamma irradiation were similar to those resulting from environmental exposures. Microscopy elemental mapping revealed patchy biofilm development, which contained Si, Al, and O, consistent with microbial-facilitated capture of clays. The plastics+biofilm of all sample types had measurable adsorption for Cs and Sr radiotracers, suggesting environmental plastics act broadly as a sink for the key pervasive environmental radionuclides of 137Cs and 90Sr associated with releases from nuclear activities. Adsorption onto high-density polyethylene plastic types was greater than that on polypropylene. However, in most cases, the adsorption rates of all types of plastic+biofilm were much lower than those of reference sediments and roughly consistent with their relative exchangeable surface areas.
More Related Videos
Related Concept Videos
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration of a Weak Acid with a Strong Base
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Weak Base Solutions
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:

