Crystallization and Structural Determination of an Enzyme:Substrate Complex by Serial Crystallography in a Versatile Microfluidic Chip
Published on: March 20, 2021
Microfluidic Mixing Injector Holder Enables Routine Structural Enzymology Measurements with Mix-and-Inject Serial
George D Calvey1, Andrea M Katz1, Lois Pollack1
1School of Applied and Engineering Physics , Cornell University , Ithaca , New York 14853 , United States.
Abstract:
The emerging technique of Mix-and-Inject Serial Crystallography (MISC) at X-ray free electron laser sources provides atomically detailed structural information about biomolecules as they function. Despite early successes, MISC is currently limited by the efficiency and robustness of the mixing injectors used to initiate the reaction and propel the sample into the X-ray beam for measurement. Here, we present a new method for fabricating the injector system that leads to simpler, faster, and more effective experiments. A mixing injector can now be produced from raw components in 100 min, only 5 min of which must be spent during the experiment, saving valuable time. The system is modular, enabling parts to be quickly exchanged in the event of unanticipated experimental difficulties, such as clogging. The injector holder is designed to be flexible, allowing each device to be optimized to maximize the number of diffraction patterns measured during each experiment. This holder has been used successfully during four beamtimes at two different X-ray free electron laser sources. Its robustness and ease of use is an important step toward making the MISC technique accessible and routine.
More Related Videos
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Mixing Concrete
Mixing Time
Ready Mixed Concrete
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Adrenergic Agonists: Mixed-Action Agents
Ephedrine and pseudoephedrine lack a catecholamine group, making them less susceptible to degradation by metabolic enzymes. They have increased oral bioavailability and lipophilicity, resulting in a longer duration of action. Their response is reduced by...