Related Experiment Video
Updated: Jan 25, 2026

Author Spotlight: Advancing DNA Extraction from Necrophilic Fly Samples using Simple Technique
Published on: May 3, 2024
DNA extraction from FFPE tissue samples - a comparison of three procedures
Agnieszka K Sarnecka1, Dominika Nawrat1, Monika Piwowar2
1Oncogene Diagnostics, Krakow, Poland.
Aim Of The Study:
One of the critical steps in molecular oncology diagnostics is obtaining high quality genomic DNA. Therefore, it is important to evaluate and compare the techniques used to extract DNA from tissue samples. Since formalin-fixed, paraffin-embedded (FFPE) tissues are routinely used for both retrospective and prospective studies, we compared three commercially available methods of nucleic acid extraction in terms of quantity and quality of isolated DNA.
Material And Methods:
Slides prepared from 42 FFPE blocks were macro-dissected. Resulting material was divided and processed simultaneously using three extraction kits: QIAamp DNA FFPE Tissue Kit (QIAGEN), Cobas DNA Sample Preparation Kit (Roche Molecular Systems) and Maxwell 16 FFPE Plus LEV DNA Purification Kit (Promega). Subsequently, quantity and quality of obtained DNA samples were analysed spectrophotometrically (NanoDrop 2000, Thermo Scientific). Results of quantitative analysis were confirmed by a fluorometric procedure (Qubit 3.0 Fluorometer, Life Technologies).
Results:
The results demonstrated that the yields of total DNA extracted using either Maxwell or Cobas methods were significantly higher compared to the QIAamp method (p < 0.001). The Maxwell Extraction Kit delivered DNA samples of the highest quality (p < 0.01). However, the highest total yield of extracted DNA was achieved with the Cobas technique, which may be due to a higher volume of eluate compared to the Maxwell method.
Conclusions:
To our knowledge, this is the first paper which directly compares three extraction methods: Cobas, Maxwell and QIAamp. The data herein provide information required for the selection of a protocol that best suits the needs of the overall study design in terms of the quantity and quality of the extracted DNA.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
DNA Isolation
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Complementary DNA
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...