Sparse sampling and reconstruction for an optoacoustic ultrasound volumetric hand-held probe
Mohammad Azizian Kalkhoran1, Didier Vray2
1CRUK Cancer Imaging Centre, Institute of Cancer Research, London, SM2 5NG, UK.
Abstract:
Accurate anatomical localization of functional information is the main goal of hybridizing optoacoustic and ultrasound imaging, with the promise of early stage diagnosis and disease pathophysiology. Optoacoustic integration to ultrasound is a relatively mature technique for clinical two-dimensional imaging, however the complexity of biological samples places particular demands for volumetric measurement and reconstruction. This integration is a multi-fold challenge that is mainly associated with the system geometry, the sampling and beam quality. In this study, we evaluated the design geometry for the sparse ultrasonic hand-held probe that is popularly associated with three-dimensional imaging of anatomical deformation, to incorporate the three-dimensional optoacoustic physiological information. We explored the imaging performance of three unconventional annular geometries; namely, segmented, spiral, and circular geometries. To avoid bias evaluation, two classes of analytical and model-based algorithms were used. The superior performance of the segmented annular array for recovery of the true object is demonstrated. Along with the model-based approach, this geometry offers spatial invariant resolution for the optoacoustic mode for the given field of view.The analytical approach, on the other hand, is computationally less expensive and is the method of choice for ultrasound imaging. Our design can potentially evolve into a valuable diagnostic tool, particularly for vascular-related disease.
Related Concept Videos
Hand hygiene
Hand washing...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Reconstruction of Signal using Interpolation
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...


