Related Experiment Video
Updated: Jan 25, 2026

AC Electrokinetic Phenomena Generated by Microelectrode Structures
Published on: July 28, 2008
Determination of nikethamide by micellar electrokinetic chromatography
Krystian Purgat1, Kamila Borowczyk1, Robert Zakrzewski1
1Department of Environmental Chemistry, Faculty of Łódź, University of Łódź, Łódź, Poland.
Abstract:
A simple, fast, sensitive and reproducible micellar electrokinetic chromatography (MEKC)-UV method for the determination of nikethamide (NKD) in human urine and pharmaceutical formulation has been developed and validated. The method exhibits high trueness, good precision, short analysis time and low reagent consumption. NKD is an organic compound belonging to the psychoactive stimulants used as an analeptic drugs. The proposed analytical procedure consists of few steps: dilution of urine or drug in distilled water, centrifugation for 2 min (12,000g), separation by MEKC and ultraviolet-absorbance detection of NKD at 260 nm. The background electrolyte used was 0.035 mol/L pH 9 borate buffer with the addition of 0.05 mol/L sodium dodecyl sulfate and 6.5% ACN. Effective separation was achieved within 5.5 min under a voltage of 21 kV (~90 μA) using a standard fused-silica capillary (effective length 51 cm, 75 μm i.d.). The determined limit of detection for NKD in urine was 1 μmol/L (0.18 μg/mL). The calibration curve obtained for NKD in urine showed linearity in the range 4-280 μmol/L (0.71-49.90 μg/mL), with R2 0.9998. The RSD of the points of the calibration curve varied from 5.4 to 9.5%. The analytical procedure was successfully applied to analysis of pharmaceutical formulation and spiked urine samples from healthy volunteers.
More Related Videos
06:16Fabrication of Spherical and Worm-shaped Micellar Nanocrystals by Combining Electrospray, Self-assembly, and Solvent-based Structure Control
Published on: February 11, 2018
09:55Preparation of Janus Particles and Alternating Current Electrokinetic Measurements with a Rapidly Fabricated Indium Tin Oxide Electrode Array
Published on: June 23, 2017
Related Concept Videos
Affinity Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Ion-Exchange Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Determining Order of Reaction
Determination