Improvement of reproducibility in quantitative susceptibility mapping (QSM) and transverse relaxation rates ( )
Joon Yul Choi1, Jingu Lee1, Yoonho Nam2
1Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea.
Background:
Numerous studies have suggested that quantitative susceptibility mapping (QSM) and transverse relaxation rates ( ) are useful to monitor neurological diseases. For clinical use of QSM and , reproducibility is an important feature. However, respiration-induced local magnetic field variation makes artifacts in gradient echo-based images and reduces the reproducibility of QSM and .
Purpose:
To investigate the improvement of reproducibility of QSM and after the correction of respiration-induced field variation, and to assess the effect of varying types of the region of interest (ROI) analysis on reproducibility.
Study Type:
Reproducibility study.
Population:
Ten controls.
Field Strength/Sequence:
3T/multiecho gradient echo sequence.
Assessment:
Intrascan reproducibility of QSM and was investigated in ROIs before and after the respiration correction.
Statistical Tests:
Reproducibility was obtained by the square of voxel-wise correlation coefficients between scans. A paired t-test was performed for comparison between before and after the respiration correction and between QSM and .
Results:
Based on the ROI analysis, reproducibility increased after the respiration correction. Reproducibility in the white matter (11.89% increased in QSM and 23.38% in , P = 0.009 and 0.024, respectively) and deep gray matter (5.50% increased in QSM and 13.96% in , P = 0.024 and 0.019, respectively) increased significantly after the respiration correction. Reproducibility of was higher than that of QSM in the whole brain and cortical gray matter, while QSM maps showed higher reproducibility than in the white matter and deep gray matter.
Data Conclusion:
Respiration-induced error correction significantly improved reproducibility in QSM and mapping. QSM and mapping showed a different level of reproducibility depending on the types of ROI analysis.
Level Of Evidence:
4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018.
Related Concept Videos
Distance Corrections
Power Factor Correction
Speed of a Transverse Wave
One of the key properties of any wave is the wave speed. Light...
Relaxation of Skeletal Muscles
When an action potential reaches the axon terminal, it depolarizes the membrane and opens voltage-gated sodium channels. Sodium ions enter the cell, further depolarizing the presynaptic membrane. This depolarization causes voltage-gated calcium channels to open....
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...