Related Experiment Video
Updated: Jan 25, 2026

An Orthotopic Glioblastoma Mouse Model Maintaining Brain Parenchymal Physical Constraints and Suitable for Intravital Two-photon Microscopy
Published on: April 21, 2014
A Physical Model Approach to Gecko Adhesion Opportunity and Constraint: How Rough Could It Be?
Peter H Niewiarowski1, Ali Dhinojwala1,2, Austin M Garner1
1Integrated Bioscience Program, Department of Biology, University of Akron, Akron, OH 44325, USA.
Abstract:
It has been nearly 20 years since Autumn and colleagues established the central role of van der Waals intermolecular forces in how geckos stick. Much has been discovered about the structure and function of fibrillar adhesives in geckos and other taxa, and substantial success has been achieved in translating natural models into bioinspired synthetic adhesives. Nevertheless, synthetics still cannot match the multidimensional performance observed in the natural gecko system that is simultaneously robust to dirt and water, resilient over thousands of cycles, and purportedly competent on surfaces that are rough at drastically different length scales. Apparent insensitivity of adhesion to variability in roughness is particularly interesting from both a theoretical and applied perspective. Progress on understanding the extent to which and the basis of how the gecko adhesive system is robust to variation in roughness is impeded by the complexity of quantifying roughness of natural surfaces and a dearth of data on free-ranging gecko substrate use. Here we review the main challenges in characterizing rough surfaces as they relate to collecting relevant estimates of variation in gecko adhesive performance across different substrates in their natural habitats. In response to these challenges, we propose a practical protocol (borrowing from thermal biophysical ecological methods) that will enable researchers to design detailed studies of structure-function relationships of the gecko fibrillar system. Employing such an approach will help provide specific hypotheses about how adhesive pad structure translates into a capacity for robust gecko adhesion across large variation in substrate roughness. Preliminary data we present on this approach suggest its promise in advancing the study of how geckos deal with roughness variation. We argue and outline how such data can help advance development of design parameters to improve bioinspired adhesives based on the gecko fibrillar system.
Related Concept Videos
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Constraints and Statical Determinacy
Directing Proteins to the Rough Endoplasmic Reticulum
Physical and Chemical Properties of Matter
The Scope of Physics
Solving Problems in Physics

