Patch testing children with aluminium chloride hexahydrate in petrolatum: A review and a recommendation
Elisabet Bergfors1, Annica Inerot2, Lars Falk3,4
1Department of Public Health and Community Medicine, Unit of Family Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden.
Background:
According to studies on adults, patch testing with aluminium chloride hexahydrate 2% pet. is insufficient to detect aluminium allergy, and a 10% preparation is recommended. Other studies suggest that a 2% preparation is sufficient for testing children.
Objectives:
To review three previously published Swedish studies on patch testing children with aluminium chloride hexahydrate 2% pet.
Patients/Methods:
Altogether, 601 children with persistent itching subcutaneous nodules (granulomas) induced by aluminium-adsorbed vaccines were patch tested with aluminium chloride hexahydrate 2% pet. and metallic aluminium in (a) a pertussis vaccine trial, (b) clinical practice, and (c) a prospective study.
Results:
Overall, 459 children had positive reactions to the 2% pet. preparation. Another 10 reacted positively only to metallic aluminium. An extreme positive reaction (+++) was seen in 65% of children aged 1 to 2 years as compared with 22% of children aged 7 years. From 8 years onwards, extreme positive reactions were scarce.
Conclusions:
Aluminium chloride hexahydrate 2% pet. is sufficient to trace aluminium allergy in children. Small children are at risk of extreme reactions. We thus suggest that aluminium chloride hexahydrate 10% pet. should not be used routinely in children before the age of 7 to 8 years.
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Long-patch Base Excision Repair
Roles of Electrolytes: Chloride and Bicarbonate
Conditions such as hypochloremia can arise from insufficient chloride reabsorption by the kidneys, often compounded by extended bouts of diarrhea, vomiting,...
Carboxylic Acids to Acid Chlorides
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...