Positive-contrast susceptibility imaging based on first-order primal-dual optimization
Caiyun Shi1,2, Jing Cheng1,2, Guoxi Xie3
1Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Science, Shenzhen, Guangdong, China.
Purpose:
To achieve faster reconstruction and better imaging quality of positive-contrast MRI based on the susceptibility mapping by incorporating a primal-dual (PD) formulation.
Methods:
The susceptibility-based positive contrast MR technique was applied to estimate arbitrary magnetic susceptibility distributions of the metallic devices using a kernel deconvolution algorithm with a regularized minimization. The regularized positive-contrast inversion problem and its PD formulation were derived. The visualization of the positive contrast and convergence behavior of the PD algorithm were compared with those of the nonlinear conjugate gradient algorithm, fast iterative soft-thresholding algorithm, and alternating direction method of multipliers. These methods were tested and validated on computer simulations and phantom experiments.
Results:
The PD approach could provide a faster reconstruction time compared with other methods. Experimental results showed that the PD algorithm could achieve comparable or even better visualization and accuracy of the metallic interventional devices in positive-contrast imaging with different SNRs and orientations to the B0 field.
Conclusion:
A susceptibility-based positive-contrast imaging technique by PD algorithm was proposed. The PD approach has more superior performance than other algorithms in terms of reconstruction time and accuracy for imaging the metallic interventional devices.
Related Concept Videos
Position of Equilibrium in Acid-Base Reactions
Position-effect Variegation
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Susceptibility, Permittivity and Dielectric Constant
Serial Position Effect