Fracture resistance and failure modes of endocrowns manufactured with different CAD/CAM materials under axial and
Wiam El Ghoul1, Mutlu Özcan2, Munir Silwadi1
1Lebanese University, Faculty of Dental Medicine, Department of Prosthodontics, Beirut, Lebanon.
Objectives:
The purpose of this in vitro study was to evaluate the fracture resistance and failure modes of endocrowns made of three computer-aided design/computer-aided manufacturing (CAD/CAM) materials subjected to thermo-mechanical cycling loading.
Materials And Methods:
Eighty mandibular molars were divided into four groups (n = 20): one (C E) was restored with lithium disilicate glass-ceramic conventional crowns, three were restored with endocrowns made of three different CAD/CAM materials; (E E) lithium disilicate glass-ceramic, (E V) zirconia-reinforced lithium silicate glass-ceramic, and (E C) resin nano-ceramic. After cycling loading, half of the samples from each group were loaded axially and the other half was loaded laterally. Fracture resistance was recorded in Newton (N) and failure modes were classified. Two-way ANOVA, Bonferroni post hoc (α = .05), Chi-square, and multiple logistic regression tests were used to analyze data.
Results:
Statistically significant interaction were recorded between fracture resistance (N) and loading (P < .001), and groups (conventuional crown and endocrowns; P < .001). Endocrowns presented higher fracture strength than conventional crowns. Fracture resistance was significantly larger under axial loading. The numbers of irreparable failures were extremely important in the endocrowns groups (Groups E E, E V, E C), and only conventional crowns (Group C E) showed almost no irreparable failures under axial loading.
Conclusion:
Lithium disilicate glass-ceramic recorded the highest fracture resistance under axial and lateral loading.
Clinical Significance:
The number of irreparable failures with all endocrown materials tested do not suggest yet the use of this type of restorations in posterior teeth.
Related Concept Videos
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Normal Strain under Axial Loading
Eccentric Axial Loading in a Plane of Symmetry
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Axial and Appendicular Muscles
Axial Muscles
Axial muscles, situated along the body's midline, are intricately connected to the axial skeleton, which includes the skull, spine, ribs, and sternum. These muscles facilitate facial expressions and...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...