Related Experiment Video
Updated: Jan 25, 2026

A Microfluidic Platform to Study Bioclogging in Porous Media
Published on: October 13, 2022
Inverse identification of a higher order viscous parameter of rigid porous media in the high frequency domain
R Roncen1, Z E A Fellah2, E Piot1
1ONERA/Département Multi-Physique pour l'Énergétique, Université de Toulouse, F-31055, Toulouse, France.
Abstract:
In this paper, a modeling extension for the description of wave propagation in rigid porous media at high frequencies is used. To better characterize the visco-inertial and thermal interactions between the fluid and the structure in this regime, two additional characteristic viscous and thermal surfaces Σ and Σ' are taken into account, as initially introduced in Kergomard, Lafarge, and Gilbert [Acta Acust. Acust. 99(4), 557-571 (2013)]. This extends the modeling order of the dynamic tortuosity and compressibility. A sensitivity analysis is performed on the additional parameters, showing that only the viscous surface Σ has an influence on transmitted waves in the high frequency regime, for materials having a low viscous characteristic length. A general Bayesian inference is then conducted to infer simultaneously the posterior probability densities of the parameters associated with the visco-inertial effects, i.e., the porosity, tortuosity, the viscous characteristic length, and the viscous characteristic surface. The proposed method is based on the measurement of waves transmitted by a slab of rigid porous material in the time domain. Bayesian inference results obtained on three different porous materials are presented.
Related Concept Videos
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Conservation of Protein Domains Over Different Proteins
A limited set of protein domains often duplicate and recombine during evolution. These domains can be organized in different combinations to...

