A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
Repair integrity and functional outcomes of arthroscopic repair for intratendinous partial-thickness rotator cuff
Kyung Cheon Kim1, Woo-Yong Lee2, Hyun Dae Shin2
11 Department of Orthopedic Surgery, Shoulder Center, TanTan Hospital, Daejeon, South Korea.
Purpose:
We evaluated the clinical and radiological outcomes of arthroscopic repair of intratendinous partial-thickness rotator cuff tears.
Methods:
We retrospectively reviewed 30 patients who underwent arthroscopic repair of intratendinous partial-thickness rotator cuff tears from January 2010 to January 2015 in a single institute. Five outcome measures were used: a visual analog scale (VAS) pain score, the American Shoulder and Elbow Surgeons score, the shoulder rating scale of the University of California at Los Angeles, the Constant-Murley score, and range of motion (ROM). Pain was recorded using the VAS. Active ROM was measured goniometrically. Rotator cuff repair integrity was determined via magnetic resonance imaging or ultrasonography at least 6 months after arthroscopic repair.
Results:
Of the 30 patients, 29 (96.6%) returned for functional follow-up evaluation no earlier than 2 years after the operation. All functional scores exhibited significant improvements (all p = 0.000). The VAS improved from a mean of 5.8 ± 1.6 to 2.5 ± 2.6 ( p = 0.000). The mean active ROM of forward flexion changed from 149.8 ± 33.8° preoperatively to 172.4 ± 9.1° ( p = 0.001) at the last follow-up; abduction changed from 115.6 ± 50.3° to 171.3 ± 15.9° ( p = 0.000). Postoperative radiological evaluation revealed retearing in three patients (3/28, 10.7%), including two with articular-side partial-thickness retears and one with a bursal-side partial-thickness retear.
Conclusion:
Arthroscopic repair of intratendinous partial-thickness rotator cuff tears was associated with a retearing rate of 10.7% on radiological follow-up and afforded significant clinical and functional improvements.
More Related Videos
07:22Arthroscopic Management of Massive Irreparable Rotator Cuff Tears: Whole Rotator Cable Reconstruction Using Proximal Biceps Tendon Autograft
Published on: June 6, 2025
04:01The Modified Single-working Portal Technique Using Lasso-loop Stitch with Needle for Arthroscopic Subscapularis Repair
Published on: August 8, 2025
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Overview of DNA Repair
Chemically...
Base Excision Repair
The first step of...
Nucleotide Excision Repair
Nucleotide Excision Repair
Cells are regularly exposed to mutagens—factors in the environment that can damage DNA and generate mutations. UV radiation is one of the most common mutagens and is estimated to introduce a significant number of changes in DNA. These include bends or kinks in the structure, which can block DNA replication or transcription. If these errors are not fixed, the damage can cause mutations, which in turn can result in cancer or disease depending on which sequences are...