Related Experiment Video
Updated: Jan 25, 2026

Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Postmortem volume change of the spleen and kidney on early postmortem computed tomography: comparison with antemortem
Naoya Takahashi1,2,3, Keisuke Yajima4,5, Madoka Otaki6,7
1Department of Radiological Technology, Graduate School of Health Sciences, Niigata University, 2-746 Asahimachi-dori, Chuoku, Niigata, Niigata, 951-8518, Japan. nandtr@clg.niigata-u.ac.jp.
Purpose:
To clarify an early postmortem change, we investigated the volume changes of the spleen and kidney on postmortem CT compared with antemortem CT in the same patients.
Materials And Methods:
We retrospectively evaluated the volumes of 56 spleens (56 cases) and 50 kidneys (25 cases) using antemortem and postmortem CT, which were performed within 168 min after death. We divided the cases of spleen analysis into a hemorrhagic group (n = 12) and a non-hemorrhagic group (n = 44).
Results:
The volumes of the organs before and after death were 101.0 ± 70.9 (cm3, mean ± standard deviation) and 81.1 ± 57.8 in spleens, 120.3 ± 49.2 and 109.2 ± 39.2 in kidneys, respectively. Both spleens and kidneys shrank after death (p < 0.05). The volumes of spleens before and after death were 111 ± 66.5 and 67.5 ± 27.7 in the hemorrhagic group, and 98.2 ± 72.5 and 84.9 ± 63.3 in the non-hemorrhagic group, respectively. The median value of the ratio of postmortem splenic volume to antemortem volume in the hemorrhagic group (65.0%) was smaller than the one in the non-hemorrhagic group (90.5%) (p < 0.05).
Conclusion:
We demonstrated that spleens and kidneys significantly reduced in size after death. The rate of shrinkage of spleens in the hemorrhagic group significantly became larger than the one in the non-hemorrhagic group.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Work Done During Volume Change
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as
Unsoundness of Aggregate due to Volume Change
Le Chatelier's Principle: Changing Volume (Pressure)
Design Example: Traverse Angle Computations

