Related Experiment Video
Updated: Jan 25, 2026

Diagnosis of Ecto- and Endoparasites in Laboratory Rats and Mice
Published on: September 6, 2011
Laboratory diagnosis of heparin-induced thrombocytopenia
Theodore E Warkentin1,2,3,4
1Department of Medicine, Michael G. DeGroote School of Medicine, McMaster University, Hamilton, Ontario, Canada.
Heparin-induced thrombocytopenia (HIT) is a clinical-pathological disorder; thus, laboratory testing for the pathogenic platelet-activating antiplatelet factor 4 (PF4)/heparin antibodies is central for diagnosis. The "iceberg" model summarizes the inter-relationship between platelet activation assays and PF4-dependent immunoassays, with platelet-activating antibodies comprising a subset of anti-PF4/heparin antibodies. The platelet serotonin-release assay (SRA), performed by reference laboratories, has high sensitivity and specificity for HIT (~95% each), and is especially suited for detecting highly pathogenic HIT sera containing both heparin-dependent and heparin-independent platelet-activating antibodies; this latter subgroup of antibodies explains "autoimmune HIT" disorders (delayed-onset, persisting, spontaneous, heparin "flush," fondaparinux-associated). Recently, SRA-negative HIT has become recognized, in which serum from some HIT patients contains subthreshold levels of platelet-activating antibodies (by SRA) that become detectable using a PF4-enhanced platelet activation assay. Unusual immunologic features of HIT include early antibody detectability (at onset of platelet count fall) and antibody transience (seroreversion). Widely available PF4-dependent enzyme immunoassays (EIAs) have high sensitivity but poor specificity for HIT, although specificity is enhanced with IgG-specific EIAs and strong positive results; unfortunately, EIA results are usually not available in real time. Automated rapid immunoassays, such as the chemiluminescence immunoassay (CLIA) and latex immunoturbidimetric assay (LIA), facilitate real-time laboratory diagnosis. Recently available likelihood ratio (LR) data for positive (LR+) and negative (LR-) test results allow clinicians to adjust their pretest probabilities for HIT, using Bayesian analysis, into real-time posttest probabilities that are dramatically increased (test positive) or decreased (test negative). Moreover, (semi-)quantitative CLIA- and LIA-positive results (weak, moderate, strong positive) can further refine the posttest probability of HIT.
Heparin-induced thrombocytopenia (HIT) is a clinical-pathological disorder; thus, laboratory testing for the pathogenic platelet-activating antiplatelet factor 4 (PF4)/heparin antibodies is central for diagnosis. The "iceberg" model summarizes the inter-relationship between platelet activation assays and PF4-dependent immunoassays, with platelet-activating antibodies comprising a subset of anti-PF4/heparin antibodies. The platelet serotonin-release assay (SRA), performed by reference laboratories, has high sensitivity and specificity for HIT (~95% each), and is especially suited for detecting highly pathogenic HIT sera containing both heparin-dependent and heparin-independent platelet-activating antibodies; this latter subgroup of antibodies explains "autoimmune HIT" disorders (delayed-onset, persisting, spontaneous, heparin "flush," fondaparinux-associated). Recently, SRA-negative HIT has become recognized, in which serum from some HIT patients contains subthreshold levels of platelet-activating antibodies (by SRA) that become detectable using a PF4-enhanced platelet activation assay. Unusual immunologic features of HIT include early antibody detectability (at onset of platelet count fall) and antibody transience (seroreversion). Widely available PF4-dependent enzyme immunoassays (EIAs) have high sensitivity but poor specificity for HIT, although specificity is enhanced with IgG-specific EIAs and strong positive results; unfortunately, EIA results are usually not available in real time. Automated rapid immunoassays, such as the chemiluminescence immunoassay (CLIA) and latex immunoturbidimetric assay (LIA), facilitate real-time laboratory diagnosis. Recently available likelihood ratio (LR) data for positive (LR+) and negative (LR-) test results allow clinicians to adjust their pretest probabilities for HIT, using Bayesian analysis, into real-time posttest probabilities that are dramatically increased (test positive) or decreased (test negative). Moreover, (semi-)quantitative CLIA- and LIA-positive results (weak, moderate, strong positive) can further refine the posttest probability of HIT.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Diabetes: Symptoms, Diagnosis, and Complications
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...